Evaluasi Sistem Koordinasi Proteksi Pada Sistem Kelistrikan Pertamina Ru Vi Balongan Dengan Mempertimbangkan Arcflash

Wisnumukti, Hartandi (2022) Evaluasi Sistem Koordinasi Proteksi Pada Sistem Kelistrikan Pertamina Ru Vi Balongan Dengan Mempertimbangkan Arcflash. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 071118400000024-Undergraduate_Thesis.pdf] Text
071118400000024-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (2MB)

Abstract

Koordinasi proteksi merupakan hal yang sangat penting bagi sebuah pembangkit sistem tenaga listrik agar tidak mengalami blackout. Sistem proteksi dapat memutus arus jika terjadi gangguan serta dapat mengamankan daerah yang tidak mengalami gangguan. Sehingga kontinuitas listrik dapat terjaga. Adanya sistem proteksi tersebut berfungsi untuk melindungi peralatan dari kerusakan dan pemadaman akibat adanya arus gangguan serta mencegah pekerja tidak terkena dampak dari busur api (arc-flash). Busur api (arc flash) adalah peristiwa lewatnya arus listrik melalui udara yang berada di antara konduktor dari fasa ke fasa atau dari fasa ke ground, suhu udara yang dilewati arus tersebut dapat mencapai 35.000°F Arc flash disebabkan karena adanya gangguan arus atau arching fault pada sebuah sistem kelistrikan. Gangguan ini dapat berupa kegagalan mekanik, kegagalan isolasi, korosi atau kesalahan manusia. Arc flash dapat menimbulkan ledakan, panas, tekanan yang besar bahkan kebakaran. Efek ini dapat merusak peralatan dan kecelakaan yang fatal pada pekerja.Dalam tugas akhir ini dilakukan evaluasi koordinasi proteksi dengan memeprtimbangkan terjadinya peristiwa arc flash dapat mengganggu keberlangsungan supply daya listrik dan mengancam keselamatan karyawan Pertamina RU VI Balongan. Hal tersebut dapat berdampak langsung terhadap produktivitas Pertamina RU VI Balongan. Sehingga peran peralatan- peralatan pengaman listrik dan koordinasinya sangat dibutuhkan untuk meminimalisir dampak yang ditimbulkan oleh gangguan tersebut. Penggunaan perlengkapan perlindungan (PPE) yang sesuai standar juga dapat meningkatkan keselamatan kerja karyawan Pertamina RU VI Balongan.
==============================================================================================================================
Protection coordination is very important for a power system generator so as not to experience blackouts. The protection system can cut off the current in the event of a disturbance and can secure areas that are not disturbed. So that electrical continuity can be maintained. The existence of this protection system serves to protect equipment from damage and blackouts due to fault currents and to prevent workers from being affected by arc-flash. Arc flash is the event of the passage of electric current through the air between the conductors from phase to phase or from phase to ground, the air temperature through which the current passes can reach 35,000°F Arc flash is caused by a current disturbance or arching fault in an electrical system. These disturbances can be in the form of mechanical failure, insulation failure, corrosion or human error. Arc flash can cause explosion, heat, great pressure and even fire. This effect can damage equipment and cause fatal accidents to workers.In this final project, an evaluation of protection coordination is carried out by considering the occurrence of arc flash events that can disrupt the continuity of the electrical power supply and threaten the safety of Pertamina RU VI Balongan employees. This can have a direct impact on the productivity of Pertamina RU VI Balongan. So that the role of electrical safety equipment and its coordination is needed to minimize the impact caused by the disturbance. The use of standardized personal protective equipment (PPE) can also improve the work safety of Pertamina RU VI Balongan employees.

Item Type: Thesis (Other)
Additional Information: RSE 621.317 Wis e-1 2022
Uncontrolled Keywords: Arc Flash. Koordinasi Proteksi. Personal Protective Equipment (PPE).
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Mr. Marsudiyana -
Date Deposited: 12 Jun 2026 07:28