Abstract

Indonesia Renal Registry (IRR) menyebutkan pada tahun 2015 terdapat 30.554 pasien aktif cuci darah yang sebagian besar merupakan pasien gagal ginjal kronik.Penyakit ginjal kronik (PGK) merupakan suatu kegagalan fungsi ginjal untuk mempertahankan metabolisme dan keseimbangan cairan serta elektrolit.Ketika ginjal tersebut tidak lagi bekerja atau mengalami kerusakan maka kemudian dibutuhkan dialisis yang dapat menggantikan fungsi pembersihan darah.Dalam proses dialisis terdapat proses penting yang disebut dengan ultrafiltrasi yang menggunakan tekanan negatif dialisat yang diatur dengan menggunakan pompa untuk mengontrol laju aliran dialisat.Sehingga dengan adanya penelitian terkait sistem kontrol aliran cairan dialisat sangat penting terkait proses ultrafiltrasi pada mesin hemodialisa.Tujuan dari penelitian ini adalah untuk mengembangkan metode sistem kontrol aliran cairan dialisat pada proses ultrafiltrasi pada mesin hemodialisis.Pada penelitian Dihasilkan instrumentasi uang dapat mengontrol aliran cairan pada balancing chamber yang terdiri atas 2 buah chamber 100mL, valve, dan pompa.Kontroler logika fuzzy digunakan pada sistem untuk mengontrol pompa yang ada berdasarkan umpan balik sensor aliran dan juga terdapat mekanisme buka tutup katup pada chamber menggunakan timer yang disesuaikan setiap siklusnya.Hasil sistem kontrol aliran dialisat yang menggunaan fuzzy logic kontroler sebagai pengontrol pompa menghasilkan kecepatan aliran yang berosilasi pada set point-nya dan sesuai dengan rentang yang diinginkan dan dengan error yang dihasilkannya sebesar 2,4%.Serta untuk buka-tutup valve memiliki tingkat keakuratan waktu untuk bekerja selama satu siklus didapatkan rata-rata errornya adalah 2,075%. ==============================================================================================================================
The Indonesian Renal Registry (IRR) states that in 2015 there were 30,554 active dialysis patients, most of whom were patients with chronic kidney failure.Chronic kidney disease (CKD) is a failure of kidney function to maintain metabolism and fluid and electrolyte balance.When the kidney is no longer working or is damaged, then dialysis is needed which can replace the function of cleansing the blood.In the dialysis process there is an important process called ultrafiltration which uses negative pressure dialysate which is regulated by using a pump to control the flow rate of the dialysate.So with research related to the dialysate fluid flow control system, it is very important related to the ultrafiltration process in hemodialysis machines.The purpose of this study was to develop a dialysate fluid flow control system method in the ultrafiltration process on a hemodialysis machine.In the research, money instrumentation can control the flow of fluid in the balancing chamber which consists of 2 100mL chambers, valves, and pumps.A fuzzy logic controller is used in the system to control the existing pump based on the flow sensor feedback and there is also a valve opening and closing mechanism in the chamber using a timer that is adjusted every cycle.The results of a dialysate flow control system that uses a fuzzy logic controller as a pump controller produces an oscillating flow velocity at its set point and in accordance with the desired range and with an error of 2.4%.And for opening and closing the valve

Item Type: Thesis (Other)
Additional Information: RSB 629.89 Per s-1 2022
Uncontrolled Keywords: Balancing chamber. Hemodialisis. Ultrafiltrasi. Dialisat. Balancing chamber. Hemodialysis. Ultrafiltration. Dialysate.
Subjects: R Medicine > R Medicine (General) > R857.M3 Biomedical materials. Biomedical materials--Testing.
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Biomedical Engineering > 11410-(S1) Undergraduate Thesis