Abstract

Pembelajaran mata kuliah Mesin Listrik di Departemen Teknik Elektro Otomasi-ITS dilengkapi dengan praktikum untuk menambah pemahaman materi. Namun, dalam kondisi saat ini terjadi pandemi Covid-19 sehingga seluruh pembelajaran dialihkan secara daring untuk menghindari penyebaran tersebut. Penerapan remote laboratory yang merupakan implementasi dari Internet of Things (IoT) sangat dibutuhkan. Hal ini memungkinkan terjadinya pengaksesan hingga penggunaan modul praktikum secara remote control pada sebuah WebAccess untuk menunjang praktikum start motor induksi 3 phasa yang terdiri dari starting Direct On Line (DOL) dan Start Wye-Delta. Metode yang digunakan dalam penelitian ini yaitu metode client- server, dimana digunakan sebagai unjuk performa WebAccess SCADA. Perancangan ini menggunakan topologi star dengan IP address yang digunakan harus sekelas dan satu network. Agar bisa berkomunikasi, client dan server harus memiliki net ID yang sama dan host ID yang berbeda untuk membedakan setiap client. IP Address yang digunakan yaitu IP Static dengan IP server telah ditentukan sebesar 10.170.81.150. Banyaknya client menjadi faktor yang dapat mempengaruhi kinerja server untuk menghantarkan perintah pada plant yang ada di laboratorium. Hasil yang telah didapat pada Proyek Akhir ini yaitu pengukuran arus dengan metode DOL menghasilkan lonjakan arus yang besarnya 1,31 A pada fasa R, 1,26 A pada fasa S, dan 1,19 A pada fasa T selama kurun waktu 1 detik, setelah waktu tersebut arus stabil dengan arus pada fasa R sebesar 0,97A, fasa S sebesar 0,97A dan fasa T sebesar 0,97A. Pada start DOL besarnya tegangan yang mengalir pada R-S sebesar 215V, R-T sebesar 225V dan S-T sebesar 215V. Pada metode wye-delta arus yang mengalir pada metode wye sebesar 0,40A, 0,38A, 0,41A, sedangkan pada metode delta sebesar 0,94A, 0,92A, 0,90A. Pada start wye-delta, tegangan pada metode wye sebesar 123V, 124V, 128V, sedangkan pada metode delta sebesar 221V, 219V, 221V. Pada pengujian unjuk kerja alat menggunakan metode client-server, diperoleh hasil rata-rata delay ketika plant dijalankan dengan besaran delay sebesar 1,18 detik.
==============================================================================================================================
Learning Electrical Machinery at the Department of Automation Electrical Engineering- ITS is equipped with practicums to increase understanding of the material. However, in the current state of the Covid-19 pandemic, all learning is diverted online to avoid the spread. The application of a remote laboratory which is an implementation of the Internet of Things (IoT) is very much needed. This allows access to the use of remote control practicum modules on a WebAccess to support the practicum of starting a 3-phase induction motor which consists of starting Direct On Line (DOL) and Start Wye-Delta. The method used in this research is the client-server method, which is used to show the performance of WebAccess SCADA. This design uses a star topology with the IP address used must be in the same class and network. In order to communicate, the client and server must have the same net ID and a different host ID to distinguish each client. The IP address used is Static IP with the server IP having been determined at 10,170.81.150. The number of clients is a factor that can affect server performance to deliver orders to plants in the laboratory. The results that have been obtained in this Final Project are current measurements using the DOL method resulting in a current surge of 1.31 A in the R phase, 1.26 A in the S phase, and 1.19 A in the T phase for a period of 1 second. At DOL start the amount of current flowing in R-S is 215V, R-T is 225V and S-T is 215V. In the wye-delta method, the current flowing in the wye method is 0.40A, 0.38A, 0.41A, while the delta method is 0.94A, 0.92A, 0.90A. In the wye-delta start, the voltage in the wye method is 123V, 124V, 128V, while the delta method is 221V, 219V, 221V. In testing the performance of the tool using the client-server method, the average delay when the plant is run is obtained with a delay of 1.18 seconds.

Item Type: Thesis (Diploma)
Additional Information: RSEO 629.8 Ram r-1 2022
Uncontrolled Keywords: Motor induksi, Starting motor, remote laboratory, metode client-server. Induction motor, Starting motor, remote laboratory, client-server method.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3070 Automatic control
Divisions: Faculty of Vocational > 36304-Automation Electronic Engineering