Abstract

Pulau Karakelang merupakan wilayah kepulauan 3T di Provinsi Sulawesi Utara yang masih menggunakan sistem kelistrikan isolated berbasis Pembangkit Listrik Tenaga Diesel (PLTD). Sistem ini menghadapi berbagai permasalahan seperti tingginya biaya bahan bakar, keterbatasan cadangan daya, serta rendahnya keandalan sistem ketika terjadi gangguan pembangkit. Kondisi tersebut mendorong perlunya pengembangan sistem hybrid berbasis energi terbarukan melalui integrasi Pembangkit Listrik Tenaga Surya (PLTS) dan Battery Energy Storage System (BESS). Penelitian ini bertujuan untuk mengevaluasi kelayakan tekno ekonomi pembangunan sistem hybrid PLTS-PLTD di Pulau Karakelang, mengidentifikasi kriteria utama yang mempengaruhi pengambilan keputusan, serta menentukan konfigurasi sistem terbaik menggunakan metode Analytical Hierarchy Process (AHP) dan Technique for Order Preference by Similarity to Ideal Solution (TOPSIS). Penelitian dilakukan menggunakan pendekatan kuantitatif dengan simulasi sistem menggunakan perangkat lunak HOMER Pro. Data yang digunakan meliputi data beban sistem, kapasitas pembangkit, biaya investasi, biaya operasional, konsumsi bahan bakar, serta data hasil kuisioner dari responden ahli. Alternatif konfigurasi sistem terdiri dari PLTD 100%, PLTS 25% + PLTD 75%, PLTS 50% + PLTD 50%, PLTS 75% + PLTD 25%, dan PLTS 100% + BESS. Sistem Hybrid PLTS-PLTD layak diterapkan pada sistem isolated Pulau Karakelang baik dari aspek teknis maupun ekonomi. Hasil simulasi HOMER Pro menunjukkan bahwa integrasi PLTS mampu menurunkan ketergantungan terhadap PLTD, mengurangi konsumsi bahan bakar diesel, serta menurunkan biaya pokok penyediaan listrik. Hasil pembobotan AHP menunjukkan bahwa aspek teknis menjadi faktor paling dominan dalam pengambilan keputusan dengan bobot sebesar 67,4%. Subkriteria keandalan sistem memperoleh bobot tertinggi sebesar 36,4%. Konfigurasi PLTS 50% + PLTD 50% merupakan alternatif paling optimal berdasarkan hasil metode TOPSIS dengan nilai preferensi sebesar 0,731. Konfigurasi ini memberikan keseimbangan terbaik antara aspek keandalan sistem, efisiensi biaya, pengurangan konsumsi BBM, serta kemampuan integrasi energi terbarukan pada sistem isolated.
=======================================================================================================================================
Karakelang Island is a remote 3T island region in North Sulawesi Province that still relies on an isolated electricity system powered by Diesel Power Plants (PLTD). This system faces several challenges, including high fuel costs, limited reserve capacity, and low system reliability during generator disturbances. These conditions highlight the need for renewable energy integration through a hybrid Solar Power Plant (PV) and Battery Energy Storage System (BESS). This study aims to evaluate the technoeconomic feasibility of a hybrid PV-PLTD system on Karakelang Island, identify the main criteria influencing decision-making, and determine the best system configuration using the Analytical Hierarchy Process (AHP) and Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) methods. The research employed a quantitative approach using system simulations with HOMER Pro. The data included load demand, power plant capacity, investment costs, operational costs, fuel consumption, and questionnaire data collected from expert respondents. The analyzed system configurations consisted of 100% Diesel, 25% PV + 75% Diesel, 50% PV + 50% Diesel, 75% PV + 25% Diesel, and 100% PV + BESS. The AHP weighting results indicate that the technical aspect is the most dominant factor in decision-making, with a weight of 67.4%. The system reliability sub-criterion obtained the highest weight, at 36.4%. Based on the TOPSIS method, the 50% PLTS + 50% PLTD configuration is the most optimal alternative, with a preference value of 0,731. This configuration provides the best balance between system reliability, cost efficiency, fuel consumption reduction, and the capability to integrate renewable energy into an isolated electricity system.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Sistem Hybrid, PLTS - PLTD, Teknoekonomi, AHP – TOPSIS, Energi Terbarukan, Hybrid System, PV-Diesel, Techno-Economic, Renewable Energy
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1056 Solar power plants. Ocean thermal power plants
Divisions: Interdisciplinary School of Management and Technology (SIMT) > 78201-System And Technology Innovation