Ramdhani, Tiara Alifinda (2026) Perbandingan Efektivitas Hidroksilamin hidroklorida, Natrium borohidrida dan Gambir (Uncaria gambir) sebagai Reduktor dalam Analisis Besi Menggunakan Spektrofotometer UV-Vis dengan Ion Pengganggu Co2+. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
5004221096-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only Download (2MB) | Request a copy |
Abstract
Besi (Fe) merupakan salah satu unsur kimia yang paling melimpah di bumi dan memainkan peran penting dalam berbagai aspek kehidupan manusia. Analisa besi menggunakan spektrofotometer UV-Vis dengan ligan 1,10-fenantrolin memerlukan tahap reduksi untuk mengubah Fe3+ menjadi Fe2+. Penelitian ini bertujuan untuk membandingkan efektivitas tiga reduktor, yaitu hidroksilamin hidroklorida (NH2OH.HCl), natrium borohidrida (NaBH4) dan gambir (Uncaria gambir) serta pengaruh gangguan ion Co2+. Penentuan panjang gelombang maksimum dilakukan pada rentang 400-600 nm. Ketiga reduktor menghasilkan panjang gelombang maksimum 510 nm dengan absorbansi 0,563 untuk NH2OH.HCl, 0,485 untuk NaBH4 dan 0,480 untuk gambir. Pada penentuan kurva kalibrasi Fe(II)-Fenantrolin didapatkan nilai koefisien determinasi (r2) 0,9927 untuk NH2OH.HCl; 0,9878 untuk NaBH4 dan 0,9913 untuk gambir. Hasil uji thitung masing-masing reduktor (NH2OH.HCl = 23,332; NaBH4 = 18,005; Gambir = 21,364) jauh melampaui nilai ttabel yang mengkonfirmasi adanya linieritas yang signifikan pada ketiga kurva kalibrasi. Pengujian gangguan ion Co2+ menunjukkan bahwa ion Co2+ menyebabkan penurunan nilai absorbansi seiring meningkatnya konsentrasi. Ion Co2+ mulai mengganggu pada konsentrasi 0,3 ppm untuk pereduksi NH2OH.HCl dengan persentase recovery sebesar 91,086 (RSD = 4,893 ppt; CV = 0,489%), pada konsentrasi 0,2 ppm untuk pereduksi NaBH4 dengan persentase recovery sebesar 92,354% (RSD = 0,000 ppt; CV = 0,000%) dan pada konsentrasi 0,1 ppm untuk pereduksi gambir dengan persentase recovery sebesar 94,599% (RSD = 0,000 ppt; CV = 0,000).
===========================================================================================================================
Iron (Fe) is one of the most abundant chemical elements on Earth and plays a vital role in various aspects of human life. The analysis of iron using a UV-Vis spectrophotometer with the 1,10-phenanthroline ligand requires a reduction step to convert Fe³⁺ to Fe²⁺. This study aims to compare the effectiveness of three reducing agents, hydroxylamine hydrochloride (NH₂OH·HCl), sodium borohydride (NaBH₄), and gambir (Uncaria gambir), as well as the effect of Co²⁺ ion interference. The maximum wavelength was determined in the 400–600 nm range. All three reducing agents produced a maximum wavelength of 510 nm with an absorbance of 0.563 for NH₂OH·HCl, 0.485 for NaBH₄, and 0.480 for gambir. In the determination of the Fe(II)-phenanthroline calibration curve, the coefficient of determination (r²) were 0.9927 for NH₂OH·HCl; 0.9878 for NaBH₄; and 0.9913 for gambir. The t-calculated values for each reducing agent (NH₂OH·HCl = 23,332; NaBH₄ = 18,005; gambir = 21,364) far exceeded the t-table values, confirming significant linearity in all three calibration curves. Testing for Co²⁺ ion interference showed that Co²⁺ ions caused a decrease in absorbance values as the concentration increased. Co2+ ions began to interfere at a concentration of 0.3 ppm for the NH2OH.HCl reducing agent, with a recovery percentage of 91.086% (RSD = 4.893 ppt; CV = 0.489%), at a concentration of 0.2 ppm for the NaBH₄ reducing agent with a recovery percentage of 92.354% (RSD = 0.000 ppt; CV = 0.000%), and at a concentration of 0.1 ppm for the gambir reducing agent with a recovery percentage of 94.599% (RSD = 0.000 ppt; CV = 0.000).
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | Fe(II)-Fenantrolin; Gambir; Hidroksilamin Hidroklorida; Natrium Borohidrida; Spektrofotometri UV-Vis; Co2+ ; Fe(II)-Phenanthroline; Gambir; Hydroxylamine Hydrochloride; Sodium Borohydride; UV-Vis Spectrophotometry |
| Subjects: | Q Science > QD Chemistry > QD75.2 Chemistry, Analytic |
| Divisions: | Faculty of Science and Data Analytics (SCIENTICS) > Chemistry > 47201-(S1) Undergraduate Thesis |
| Depositing User: | Tiara Alifinda Ramdhani |
| Date Deposited: | 04 Aug 2026 00:51 |
| Last Modified: | 04 Aug 2026 00:51 |
| URI: | http://repository.its.ac.id/id/eprint/142528 |
Actions (login required)
![]() |
View Item |