Farhan, Laode Ahmad (2026) Pengaruh Variasi Faktor Air Semen Terhadap Tren Workabillity Berbahan Beton Semen Hijau Portland Composite Cement (PCC). Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
10111910010069-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only Download (6MB) | Request a copy |
Abstract
Penggunaan material ramah lingkungan dalam industri konstruksi kini menjadi prioritas, salah satunya melalui pemanfaatan green cement (Portland Composite Cement/PCC). Meskipun diklaim mampu mereduksi emisi karbon, karakteristik kelecakan (workability) material ini saat diaplikasikan sebagai beton segar perlu dievaluasi dengan cermat guna memastikan kelayakannya di lapangan. Penelitian ini bertujuan untuk mengkaji tingkat workability campuran beton segar yang sepenuhnya menggunakan green cement untuk desain target mutu struktural 25 MPa. Metode perancangan campuran (mix design) dilakukan berdasarkan standar SNI 7656:2012, dengan melakukan uji slump pada FAS dengan jumlah semen yang digunakan tetap, sedangkan penggunaan air divariasikan untuk menghasilkan FAS 0,50; 0,55; dan 0,60. Hasil pengujian laboratorium menunjukkan bahwa campuran beton green cement memiliki sensitivitas tinggi terhadap variasi volume air. Pengujian pada FAS 0,50 menghasilkan nilai slump 60 mm , sedangkan FAS 0,60 menghasilkan slump mencapai 180 mm. Kinerja workability paling optimal dicapai pada variasi FAS 0,55 yang menghasilkan nilai slump 100 mm. Angka ini memenuhi target rencana spesifikasi pengerjaan konstruksi standar. Kesimpulannya, penggunaan green cement mampu memberikan tingkat workability yang ideal dan memenuhi standar pengerjaan di lapangan asalkan menggunakan proporsi FAS yang presisi.Kata kunci: Beton struktural, Uji Slump, Semen PCC, Semen hijau
==================================================================================================================================
The use of environmentally friendly materials in the construction industry is now a priority, one of which is through the use of green cement (Portland Composite Cement/PCC). Although claimed to be able to reduce carbon emissions, the workability characteristics of this material when applied as fresh concrete need to be carefully evaluated to ensure its feasibility in the field. This study aims to assess the workability level of fresh concrete mixes that fully use green cement for a structural quality target design of 25 MPa. The mix design method is carried out based on the SNI 7656:2012 standard, by conducting slump tests on FAS with a fixed amount of cement used, while the use of water is varied to produce FAS 0.50; 0.55; and 0.60. Laboratory test results show that the green cement concrete mixture has a high sensitivity to variations in water volume. Testing at FAS 0.50 produced a slump value of 60 mm, while FAS 0.60 produced a slump of up to 180 mm. The most optimal workability performance was achieved at the FAS 0.55 variation which produced a slump value of 100 mm. This figure meets the target of the standard construction work specification plan. In conclusion, the use of green cement can provide an ideal level of workability and meet work standards in the field as long as it uses precise FAS proportions. Keywords: Structural concrete, Slump Test, PCC Gresik Cement, Green cement
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | Beton struktural, Uji Slump, Semen PCC, Semen hijau Structural concrete, Slump Test, PCC Gresik Cement, Green cement |
| Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TA Engineering (General). Civil engineering (General) > TA418.16 Materials--Testing. |
| Divisions: | Faculty of Vocational > 22301-Civil Infrastructure Engineering (D4) |
| Depositing User: | Laode Ahmad Farhan |
| Date Deposited: | 18 Nov 2026 01:39 |
| Last Modified: | 18 Nov 2026 01:44 |
| URI: | http://repository.its.ac.id/id/eprint/146069 |