Silalahi, Oktavia Ully Artha (2017) Modifikasi Perencanaan Struktur Gedung Hotel Royal Darmo Yogyakarta Menggunakan Steel Plate Shear Wall (SPSW). Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
3114106060-Undergraduate_Theses.pdf Download (9MB) | Preview |
Abstract
Struktur bangunan bertingkat rawan terhadap gaya lateral, terutama akibat gaya yang ditimbulkan gempa. Indonesia juga termasuk ke dalam wilayah yang memiliki intensitas terjadi gempa tinggi, salah satunya adalah daerah yogyakarta. Perkembangan ilmu pengetahuan dan teknologi telah memunculkan salah satu solusi untuk meningkatkan kinerja struktur bangunan tinggi yaitu dengan pemasangan dinding geser plat baja (steel plate shear wall). Dinding geser plat baja (steel plate shear wall) adalah sebuah sistem penahan beban lateral yang terdiri dari plat baja vertikal padat yang menghubungkan balok dan kolom di sekitarnya yang terpasang sepanjang ketinggian struktur sehingga membentuk sebuah dinding penopang. Tugas akhir ini diharapkan dapat menjadi rekomendasi untuk proyek lain yang serupa, agar dapat memanfaatkan material baja sebagai bahan struktur gedung dengan pertimbangan keuntungan penggunaan material baja sebagai struktur gedung.
Pada perhitungan struktur gedung dengan sistem SPSW ini mengacu pada peraturan-peraturan yang berlaku di antaranya SNI 1726:2012 tentang Tata Cara Perencanaan Ketahanan Gempa untuk Bangunan Gedung dan Non Gedung, SNI 1727:2013 tentang Beban Minimum untuk Perancangan Bangunan Gedung dan Struktur Lain, SNI 2847:2013 tentang Persyaratan Beton Struktural untuk Bangunan Gedung, , SNI 1729:2015 tentang Spesifikasi untuk Bangunan Gedung Baja Struktural dan PPIUG 1983 tentang Peraturan Pembebanan Indonesia Untuk Gedung. Dalam menganalisis strukturnya ditinjau dengan pengaruh beban gempa dinamik dengan menggunakan program bantu SAP 2000.
Dari analisis dan hasil perhitungan diperoleh hasil, yaitu : tebal plat atap 9 cm, pelat lantai 9 cm, pelat koridor 9 cm, dimensi balok induk lantai2-4 WF 800.300.14.26, lantai 5-7 WF 700.300.13.20, lantai 8-10 WF 600.300.12.20, lantai atap WF 500.200.10.16, dimensi kolom lantai 1-4 HSS 800.800.25.25, lantai 5-7 HSS 700.700.25.25, lantai 8-10 HSS 600.600.19.19. Perencanaan pondasi menggunakan pondasi tiang pancang beton pracetak diameter 50 cm dengan kedalaman 16 m. Sloof ukuran 40 cm x 60 cm dengan tulangan utama 4D19 dan tulangan geser Ø12-150=================================================================================
Structure of multistory buildings are prone to lateral force, especially due to the force created by the earthquake. Indonesia is also included in the territory which has a high-intensity earthquake, which is the Yogyakarta area. The development of science and technology have been bring up the one of the solutions to improve the performance of building structures as high as with the installation of steel plate shear wall (SPSW). Steel plate shear wall is a lateral load resisting system consisting of vertical steel plate infills connected to the surrounding beams and columns and installed in one or more bays along the full height of the structure to the form a cantilever wall.
In the calculation building structures with SPSW system refers to the applicable regulations including ISO 1726:2012 about Earthquake Resistance Planning Procedures for Building Structures and Non Building, ISO 1727:2013 about Minimum Load to Design Building and Other Structure, ISO 2847:2013 about Concrete Structural Requirements for Building Structures, ISO 1729:2015 about Specifications for Structural Steel Building Structures and Loading Regulation Indonesia for Building Structures PPIUG 1983. In process analyzing, structure will reviewed by the effect of dynamic of earthquake loads by using auxiliary program SAP 2000.
From the analysis and the calculation results, are : rooftop plate thickness 9 cm, 9 cm floor plate, 9 cm corridor plate, the dimensions of the floor beam 2-4 WF 800.300.14.26, 5-7 floor is WF 700.300.13.20, 8-10 floor is 600.300.12.20, rooftop floor WF 500.200.10.16, dimension of column at floor 1-4 is HSS 800.800.25.25, 5-7 floor is HSS 700.700.25.25, 8-10 floor is HSS 600.600.19.19. Foundation design using precast concrete piles diameter 50 cm with a depth of 16 m. Sloop with of 40 cm x 60 cm with the main reinforcement and shear reinforcement Ø12-150 4D19.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Daktilitas, Dinding Geser, Modifikasi, Plat Baja |
Subjects: | T Technology > TH Building construction |
Divisions: | Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis |
Depositing User: | OKTAVIA ULLY ARTHA SILALAHI |
Date Deposited: | 31 Mar 2017 07:10 |
Last Modified: | 05 Mar 2024 10:34 |
URI: | http://repository.its.ac.id/id/eprint/2741 |
Actions (login required)
View Item |