Kompresor adalah suatu peralatan yang berfungsi untuk
mengalirkan atau menambah energi (tekanan) pada fluida
kerjanya dalam hal ini adalah fluida kompresibel. Pada industri
migas, terdapat satu komponen penting yang berperan besar
dalam membantu proses pengolahan gas yang terdapat pada
crude oil , yaitu kompresor. Kompresor mengalirkan gas dari
satu komponen ke komponen yang lain dengan tujuan agar gas
mendapat kenaikan tekanan dan dapat memasuki komponen lain
sesuai dengan tekanan yang diijinkan pada alat tersebut.
Gas yang terbawa oleh crude oil merupakan gas dengan
sebutan sour gas atau hydrogen sulfide ( H2S ) yang merupakan
gas beracun dan sangat berbahaya apabila sampai terlepas di
udara bebas. Oleh karena itu dilakukan perhitungan ulang
instalasi kompresor yang melayani aliran sour gas hingga masuk
kedalam Sulfur Recovery Unit ( SRU ). Setelah dilakukan
perhitungan maka akan diketahui brapa daya yang dibutuhkan
kompresor untuk beroperasi.
Dari hasil perhitungan didapatkan kapasitas perhari
sebesar 2949,675 m3/jam, dengan daya 411,564 KW lebih rendah
dari daya yang tertera pada name plate yang sebesar 413 KW,
kerugian tekanan yang terjadi pada sepanjang instalasi
kompresor adalah sebesar 42620 Pa. Dan perbandingan antara
perhitungan manual dan perhitungan numerik dengan software
pipe flow expert didapat hasil dengan tingkat kesalahan sebesar
0,73%.
=======================================================================================================
The compressor is a device that serves to drain or add
energy (pressure) at work in this fluid is a compressible fluid. In
the oil and gas industry, there is one important component that
plays a major role in helping the processing of gas contained in
crude oil, the compressor. Compressor gas flow from one
component to another with the purpose to increase the gas
pressure and can get into the another component in accordance
with the allowable pressure on the tools.
The gas is carried away by crude oil as sour gas or
hydrogen sulfide gas (H2S) is a toxic and dangerous gases to be
separated when in free air. Therefore the re-calculation is done
compressor installations that serve sour gas streams to enter the
Sulfur Recovery Unit (SRU). After calculation it will be known
how much power is required to operate the compressor
From the calculation results obtained by 2949.675 m3
per day capacity, the power is lower than 411.564 KW of power
indicated on the name plate is 413 KW, pressure losses that
occur during the installation of the compressor is equal to 42 620
Pa. And the comparison between manual calculations and
numerical calculations with software pipe flow expert the results
obtained with an error rate of 0.73%.

Item Type: Thesis (Diploma)
Additional Information: RSM 621.51 Att p
Uncontrolled Keywords: Sour gas, Tekanan , Kapasitas dan Daya
Subjects: T Technology > T Technology (General)
T Technology > TJ Mechanical engineering and machinery
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21401-(D3) Diploma 3
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 01 Mar 2017 02:36
Last Modified: 18 Dec 2017 01:39
URI: http://repository.its.ac.id/id/eprint/41139

Actions (login required)

View Item View Item