Unjuk Kerja Lpg Engine-Generator Set Menggunakan Syn-Gas Gasifikasi Batubara Dengan Variasi Derajat Pengapian Dan Tekanan Masuk Syn-Gas

Prasetyo, Edy (2015) Unjuk Kerja Lpg Engine-Generator Set Menggunakan Syn-Gas Gasifikasi Batubara Dengan Variasi Derajat Pengapian Dan Tekanan Masuk Syn-Gas. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2112204803-Undergraduate Thesis.pdf]
Preview
Text
2112204803-Undergraduate Thesis.pdf - Published Version

Download (4MB) | Preview

Abstract

Syn-gas gasifikasi batubara memiliki keunggulan seperti harganya murah,
nilai kalor yang relatif tinggi dan menghasilkan polusi yang rendah. Syn-gas
gasifikasi batubara tersusun atas karbon monoksida, hidrogen dan karbon
dioksida. Pada penelitian ini menggunakan syn-gas gasifikasi batubara pada LPG
engine-generator set dengan cara memvariasikan derajat pengapian dan tekanan
masuk syn-gas untuk mendapatkan unjuk kerja engine yang optimal.
Mesin uji yang digunakan dalam penelitian ini yaitu LPG Engine-
Generator set berkapasitas 4,6 kW berbahan bakar LPG. Menggunakan dua
variasi yaitu pertama memvariasikan tekanan masuk syn-gas mulai dari 500 mbar
sampai 1100 mbar, dengan interval 200 mbar. Variasi kedua yaitu pengaturan
derajat pengapian pada engine, dimana derajat pengapian divariasikan mulai dari
20o sampai 26o derajat sebelum TMA (titik mati atas) dengan interval 2 derajat,
dengan menyetting derajat pengapian pada komputer yang telah diprogram untuk
sistem pengapian ECU programable sehingga akan diperoleh derajat pengapian
yang tepat.
Hasil penelitian menunjukkan bahwa dengan sistem ECU programmable,
gas engine dengan spesifikasi 4-langkah, 1 buah silinder bertipe LPG engineset
bisa beroperasi dengan menggunakan bahan bakar 100% syn-gas gasifikasi
batubara. Saat menggunakan bahan bakar LPG, nilai variasi optimum terjadi
pada derajat pengapian sebesar 26o sebelum TMA dan tekanan masuk 70 mbar,
yaitu dapat meningkatkan kinerja berupa peningkatan daya sebesar 29,1% dan
penurunan Sfc sebesar 11,8% terhadap kondisi awal. Sedangkan saat
menggunakan bahan bakar syn-gas, nilai variasi optimum terjadi pada derajat
pengapian sebesar 26o sebelum TMA dan tekanan masuk 900 mbar, yaitu dapat
meningkatkan kinerja berupa peningkatan daya sebesar 76,5% dan penurunan
Sfc sebesar 20,5% terhadap kondisi awal.
============================================================================================
Syn-gas from coal gasification have special quality like cheap, heating
value relative high and low emissions. The main constituents of syn-gas from coal
gasification are carbon monoxide(CO), hydrogen (H2) and carbon dioxide(CO2).
This research is use syn-gas as fuel at LPG engine-generator set by advanced
ignition variation and fuel pressure supplay variation for get optimum
performance of engine.
This research use LPG engine-generator set for engine test, which it have
4,6 kW electric capacity with original fuel is LPG. The experiment use two
variation, first variation is fuel pressure supplay from 500 until 1100 mbar with
200 mbar interval. Second variation is advanced ignition from 20o until 26o
before top dead center (BTDC) with 2 degree interval. Arragement of advanced
ignition is use ECU programmable by computer.
The conclusion of this experiment gas engine by ECU programmable, gas
engine have one stroke and one silinder, its can operation with syn-gas from coal
gasification. When engine use LPG’s fuel at 26o BTDC and fuel pressure 70mbar,
engine has increasing performace for excample power increase 29,1% and sfc
decrease 11,8% than beginning condition. When engine use syn-gas’s fuel at 26o
BTDC and fuel pressure 900mbar, engine has increasing performace for
excample power increase 76,5% and sfc decrease 20,5% than beginning
condition.

Item Type: Thesis (Masters)
Additional Information: RTM 621.313 Pra u
Uncontrolled Keywords: LPG, Syn-gas batubara, LPG engine-generator set, tekanan masukan, derajat pengapian
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ164 Power plants--Design and construction
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1318 Geothermal Power Plants
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21101-(S2) Master Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 09 Jun 2017 06:20
Last Modified: 24 Aug 2018 04:17
URI: http://repository.its.ac.id/id/eprint/41561

Actions (login required)