Modifikasi Struktur Gedung Dental Nano Dengan Metode SRPMK Dan Shearwall (Dual System) Pada Wilayah Gempa Tinggi Dan Metode Kontruksi Kolom

Kusuma, Rafael Dani (2017) Modifikasi Struktur Gedung Dental Nano Dengan Metode SRPMK Dan Shearwall (Dual System) Pada Wilayah Gempa Tinggi Dan Metode Kontruksi Kolom. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3113041095-Undergraduate_Theses.pdf]
Preview
Text
3113041095-Undergraduate_Theses.pdf - Published Version

Download (24MB) | Preview

Abstract

Terbatasnya lahan saat ini menjadi salah satu kendala untuk membangun suatu bangunan. Sebagai alternatif, pembangunan gedung secara vertikal dapat menjadi solusi terbaik. Karena skala bangunan tinggi, maka memerlukan sistem penunjang struktur yang cukup rumit dimana saat bangunan telah digunakan, struktur dapat menahan gaya-gaya vertikal, dan horizontal akibat gaya gempa. Untuk memenuhi syarat bangunan “nyaman”, maka deformasi bangunan tidak boleh besar. Untuk itu, struktur gedung harus kaku.
Dalam Tugas akhir ini, dari hasil analisa struktur akibat pemindahan lokasi dari kota Malang ke kota Serui mengakibatkan sistem struktur pada gedung dental Nano yang sebelumnya merupakan Sistem Rangka Pemikul Momen dimodifikasi menjadi sistem rangka pemikul momen khusus dan dinding Geser ( Sistem Ganda ) berdasarkan SNI Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung (SNI 1726-2012). Program bantu yang digunakan dalam tugas akhir ini yaitu Structur Analysis Program (SAP 2000 V19) untuk pemodelan struktur, SPColumn 5.1 dan Autocad 2015 untuk penggambaran teknik.
Dari hasil analisa dan perhitungan struktur dihasilkan tebal pelat lantai 12 cm, tebal pelat bordes dan tangga 15 cm, dimensi balok sekunder 30/50, balok bordes 30/40, balok lift 30/50, balok Induk B1 50/70, kolom K1 85/85, dan tebal dinding geser 40 cm. Hasil analisis menunjukan bahwa perilaku struktur bangunan apabila berada di daerah gempa tinggi menjadi lebih baik dengan adanya penambahan dinding geser. Metode pelaksanaan kolom menggunakan sistem Peri, dari hasil pembahasan didapatkan durasi waktu untuk 1 item kolom K1 dengan volume kolom sebesar 3,0345 m3 mulai dari pekerjaan marking as kolom hingga perawatan kolom adalah 227 menit. =================================================================
Insufficient Area is currently one of the obstacles to construct a building. Alternatively, multy-storey building can be the best solution. Due to high scale of the buildings, it requires a complex structural support system to withstand vertical forces, and horizontally forces due to earthquake.. To qualify a "comfortable" building, the deformation of the building should not be too large. Therefore, the structure must be rigid.
in this final project, the result of structural analysis due to the transfer of location from Malang city to Serui city conduced modification in the structural system in the Nano dental building which previously was the special moment resisting frames into special moment resisting frames and shear wall (dual system) based on Procedures for Earthquake Resistance Planning for Building Structure and Non Building Standard (SNI 1726-2012). The auxiliary program used in this final project is Structur Analysis Program (SAP 2000 V19) for structural modeling and Autocad 2015 for engineering drawing.
From the result of structure analysis and calculation obtained 12 cm thickness of floor slab, 15 cm thickness of Stair slab, secondary beam dimension 30/50, bordes beam dimension 30/40, elevator beam dimension 30/50, primary beam B1 dimension 50/70 , Column K1 dimension 85 / 85, and 40 cm thickness of shear wall. The result of the analysis shows that the behavior of the building structure at high quake area prone becomes more better with the addition of shear wall. The column contruction method using Peri system, from the results obtained that the duration for 1 item K1 column its volume is 3,0345 m3 strating from marking as column until column treatmentis 227 minutes.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Perencanaan Struktur Tahan Gempa, Respons Spektrum, Sistem Ganda, Dinding Geser, Planning Earthquake Resisting Structures, Spectrum Response, Dual System, Shearwall
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA681 Concrete construction
Divisions: Faculty of Vocational > Civil Infrastructure Engineering (D3)
Depositing User: Kusuma Rafael Dani
Date Deposited: 09 Nov 2017 05:27
Last Modified: 05 Mar 2019 07:37
URI: http://repository.its.ac.id/id/eprint/43063

Actions (login required)

View Item View Item