Kawasan Medokan Semampir di Kota Surabaya memiliki sistem drainase yaitu sistem drainase Medokan Semampir. Pada sistem drainase ini ada 1 pintu air dan 3 buah rumah pompa. Menurut peta genangan tahun 2016, genangan pada kawasan Medokan Semampir seluas 60 Ha, kedalaman 30 - 50 cm, dan lama genangan 1 – 2 jam. Sebagai daerah perkotaan, kawasaan Medokan Semampir seharusnya bebas dari ancaman banjir.
Tugas Akhir ini bertujuan untuk melakukan evaluasi drainase kawasan Medokan Semampir agar dapat menurunkan genangan pada debit banjir rencana dengan periode ulang 10 tahunan. Debit banjir rencana didapatkan dari hasil analisa hidrologi. Debit banjir rencana dengan kondisi pintu air dibuka dan pompa air tidak dioperasikan akan dibandingkan dengan dengan kapasitas saluran primer. Debit banjir rencana ini juga disimulasikan dengan 2 kondisi lain. Kondisi ke 2 yaitu dengan pintu air dibuka dengan pompa air dioperasikan dan kondisi ke 3 yaitu dengan pintu air ditutup dengan pompa air dioperasikan. Ketiga kondisi debit banjir rencana ini dipilih yang terbesar dan dibandingkan dengan kapasitas saluran primer.
Dari hasil evaluasi analisa sistem drainase, debit banjir rencana kondisi ke 3 adalah debit banjir terbesar dan melebihi kapasitas saluran primer, sehingga diperlukan normalisasi pada saluran primer. Normalisasi saluran primer dilakukan dengan pelebaran penampang 800 – 900 dilebarkan menjadi 6,5m, 900 - 1.200 menjadi 7m, 1.200 – 1.600 menjadi 8m, 1.600 – 2.500 menjadi 10m, normalisasi juga dilakukan dengan menambah kedalaman saluran, yaitu pada penampang saluran 600 - 800 menjadi 1,4 m dan 800 – 2.700 menjadi 1,5 m.

================================================================

Medokan Semampir area in Surabaya City has a drainage system that is drainage system of Medokan Semampir. In this drainage system there is 1 sluice gate and 3 pump house. According to the 2016 flood map, flood in Medokan Semampir area about 60 Ha, 30-50 cm in depth, and lasts for 1 – 2 hours. As an urban area, Medokan Semampir area should be floodfree.
This final project purpose to evaluate drainage of Medokan Semampir area in order to decrease the flood in 10 year planned flood discharge. Planned flood discharge is calculated by hydrologic analysis. Planned flood discharge with the sluice gate condition are opened and the water pump not operated compared with channal capacity. Planed flood discharge is also simulated with 2 other conditions. The second condition is with the sluice gate opened with the water pump operated and the third condition to is with the sluice gate closed with water pump operated. The three planned flood discharge conditions were selected the biggest and compared with the capacity of the primary channel.
From the evaluation result of drainage system analysis, the trhird condition is the biggest planned flood discharge exceeding the capacity of the primary channel, thus the normalization of primary channels is required. Normalization of the primary channel is carried out at a cross-section of 800 - 900 extended to 6.5m, 900 - 1,200 to 7m, 1,200 - 1,600 to 8m, 1,600 -2,500 to 10m, normalization is also done by add channel depth, at a cross-section 600 – 800 to 1.4m and 800 - 2,700 to 1.5 m.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Sistem Drainase Kawasan, Evaluasi Drainase, Normalisasi Saluran
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TC Hydraulic engineering. Ocean engineering
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis