Memaksimalkan Daya Keluaran Sistem Pembangkit Listrik Sel Surya Yang Tertutup Bayangan Menggunakan Rangkaian Matriks Saklar Berbasis Logika Fuzzy Dan Regulator Tegangan Berbasis Kontroler Pid

Freitas, Basilio Mendonca (2017) Memaksimalkan Daya Keluaran Sistem Pembangkit Listrik Sel Surya Yang Tertutup Bayangan Menggunakan Rangkaian Matriks Saklar Berbasis Logika Fuzzy Dan Regulator Tegangan Berbasis Kontroler Pid. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 07111550028001-Master_Theses.pdf]
Preview
Text
07111550028001-Master_Theses.pdf - Accepted Version

Download (4MB) | Preview

Abstract

Berdasarkan penelitian-penelitian terdahulu, pada umumnya metode yang
digunakan untuk memaksimalkan daya keluaran dari photovoltaic (PV) adalah
dengan menggunakan mekanisme Maximum Power Point Tracking (MPPT). Pada
kasus PV string yang sebagian modulnya tertutup bayangan (shading) yang
bervariasi, maka sistem kontrol berbasis MPPT ini tidak dapat bekerja dengan
baik. Hal itu diakibatkan efek shading yang bervariasi, sehingga daya PV Farm
yang dihasilkan tidak optimal.
Penelitian ini menawarkan suatu metode alternatif untuk mengoptimasi
daya PV Farm berbasis cluster tegangan string PV. Dimana kapasitas daya
terpasang pada penelitian ini adalah 12000 Wp, terdiri dari 4 string PV dan setiap
stringnya terdiri dari 12 Modul, sehingga total modul PV yang digunakan sebanyak
48 modul PV. Modul-modul PV yang terdapat pada string PV dihubungkan secara
seri. Dimana akibat variasi efek shading maka besar tegangan antar string PV
berpotensi berbeda. Perbedaan tersebut mengakibatkan kesulitan dalam hal disain
Mekanisme Maximum Power Point Trucking (MPPT). Untuk itu diusulkan suatu
metode pengelompokan besar tegangan yang bersesuaian dari setiap keluaran hasil
mekanisme MPPT, dimana setiap keluaran MPPT terhubung secara paralel pada
rangkaian matrik saklar. Rangkaian matriks saklar dikontrol menggunakan
mekanisme algoritma Fuzzy Logic Controller (FLC). Selanjutnya masing-masing
hasil pengelompokan dihubungkan ke suatu rangkaian regulator berbasis kontroler
Proportional - Integral-Derivatif (PID controller) yang berfungsi mengontrol
besar tegangan setiap kelompok menjadi sama sesuai setpoint yang diinginkan.
Berdasarkan pengujian Pembangkit PV Array menggunakan metode
cluster untuk kasus tertutup bayangan sebagian terjadi peningkatan daya yang
sangat signifikan bahkan sampai dengan 108%, jika dibandingkan pembangkit PV
Array dengan menggunakan metode konvensional (tanpa cluster). Namun hal
tersebut dapat bervariasi mengikuti dinamika bayangan yang menutupi modulmodul
PV yang terdapat pada pembangkit PV Array. Maka dapat ditarik
kesimpulan bahwa metode yang diusulkan dapat bekerja dengan baik untuk
meningkatkan daya PV Array pada kondisi normal maupun tertutup bayangan
sebagian
=========================================================================================================
Based on previous studies, the method used to maximize the output power
of photovoltaic (PV) is by using Maximum Power Point Tracking (MPPT)
mechanism.
In the case of PV strings that some of the modules are covered with
varying shading, the MPPT
-
based cont
rol system can not work properly. This is
due to the effects of shading vary, so the PV Farm power generated is not optimal.
T
his research offers an alternative method to optimize PV Arrayr based
cluster of PV string. Where the power capacity installed in
this research is 12000
Wp, consisting of 4 string of PV and each string consist of 12 Modules, so total of
PV module used is 48 PV modules.
The PV modules contained in the PV strings
are connected in series. Where due to variations of shading effect, the
voltage
between the PV strings is potentially different.
This difference leads to difficulties
in designing the Maximum Power Point Tracking Mechanism (MPPT). this researc
propose a method of grouping the corresponding voltage according to each output
o
f the MPPT mechanism, in which each MPPT output is connected in parallel to
the switch matrix circuit.
The logic of this switch matrix circuit is generated using
fuzzy logic inference mechanism. Furthermore, each grouping result is connected
to a regulator
circuit based on Proportional
-
Integral
-
Derivative (PID) controller
to control the voltage of each group to be the same according to the desired setpoint.
The voltage output of this proposed system will be compared with the
voltage output of system wi
th MPPT optimization method. Based on PV PV array
testing using cluster method for closed partial shadow case, there is a very
significant increase of power even up to 10
8
%, when compared to PV Array plant
using conventional method (without cluster). Howev
er, it may vary according to
the shadow dynamics that cover the PV modules contained in the PV array
generator. So with the explanation can be concluded that the proposed method can
work well to increase the power of PV Array in normal conditions as well a
s tertup
partial shadow.

Item Type: Thesis (Masters)
Additional Information: RTE 621.312 44 Fre m-1 3100018074190
Uncontrolled Keywords: PV, MPPT, FL, dan PID Controller.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1087 Photovoltaic power generation
Divisions: Faculty of Electrical Technology > Electrical Engineering > 20101-(S2) Master Thesis
Depositing User: Basilio Mendonca Freitas
Date Deposited: 21 Feb 2018 02:37
Last Modified: 30 Apr 2020 12:33