Produksi bakso umumnya di masyarakat adalah menggunakan metode yang masih manual, yaitu dengan mencetak bakso pada sendok makan dengan tenaga manusia. Namun dewasa ini, cara manual seperti itu sudah tidak mampu lagi digunakan untuk memenuhi permintaan pasar. Oleh karena itu, dirancang sebuah alat pencetak bakso yang terkendali.
Pengendalian level pada plant finishing pencetak bakso ini menggunakan sensor light dependent resistor (LDR) sebagai sensor level. Solenoid valve sebagai aktuator pembuangan dan pemasukan air ke plant. Dimana ouput sensor akan diterima oleh ADC dari mikrokontroler ATMega 8535 sebagai kontroler dan kemudian dilanjutkan ke aktuator untuk mengeksekusi perintah..
Pemasangan tiga buah sensor pada bejana plastik untuk pengukuran level harus memperhatikan ketinggian serta peletakan, karena sensor LDR sangat sensitif terhadap intensitas cahaya.
==========================================================================================================
Generally meatballs production in the public are using the manual method, is by printing meatballs with tablespoon on human power. But today, the manual way as it is no longer able to be used to meet the market demand. Therefore, a tool designed meatballs controlled printer.
The level controlling of meatballs printer finishing plant is uses light dependent resistor sensors (LDR) as a sensor level. Solenoid valve as actuator discharge and water intake to the plant. Where the sensor output will be received by the ADC of the microcontroller ATMega 8535 as controller and then proceed to the actuator to execute the command.
Installation of three sensors on plastic vessel for level measurement should pay attention to height and positioning, because the LDR sensor is very sensitive to light intensity.

Item Type: Thesis (Diploma)
Additional Information: RSF 629.895 Sar r
Uncontrolled Keywords: pengendalian level, sensor LDR, mikrokontroler
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ223 PID controllers