Farida, Lenny (2006) Analisa Keandalan Terhadap Kelelahan Pada Struktur Kaki Jack Up Platform. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
4301100051-Undergraduate-Thesis.pdf - Published Version Download (21MB) | Preview |
Abstract
Adanya pengaruh beban lingkungan (gelombang) yang bersifat acak dapat mempengaruhi perilaku struktur Jack Up platform.. Seiring dengan berjalannya masa operasi dari struktur maka sangat penting untuk melakukan analisa keandalan terhadap kelelahan dengan maksud agar mendapatkan indeks keselamatan. Dalam hal ini variabel yang digunakan berupa variabel acak dari beban operasional akibat beban gelombang yang mempengaruhi analisa umur kelelahan struktur dengan mempertimbangkan rentang tegangan yang terjadi selama struktur beroperasi. Penyederhanaan dalam metode analisis ini dilakukan dalam model peluang matematik dengan terlebih dahulu menentukan variabel acak yang berupa faktor beban dan factor ketahanan. Struktur yang akan dianalisa adalah Jack Up Hang Tuah MOgPU platform milik Conoco Indonesia INC.LTD. Periode natural dari struktur ini didapatkan sebesar 3,25 detik sehingga sangat dianjurkan untuk menggunakan metode pendekatan stokastik (spectral fatigue analysis) dalam analisa umur kelelahannya akibat beban siklis yang terjadi selama operasi, seperti yang terdapat pada API RP-2A WSD 21. Distribusi peluang yang digunakan untuk analisa umur kelelahan adalah distribusi Rayleigh dan distribusi Weibull. Dari basil spectral fatigue analysis dengan menggunakan pesamaan kelelahan terangkai (closed form fatigue equation) didapatkan umur kelelahan struktur selama masa operasi adalah sebesar 86 tahun dengan indeks keandalan sebesar 2,09 sebagai initial condition, untuk service life 25 tahun dimana joint kritisnya adalah D7523 pada member TD6929. Pada tahap analisa keandalan struktur, metode yang digunakan adalah metode Advanced First Order Second Moment (AFOSM). Untuk keperluan perencanaan
inspeksi maka diperlukan grafik degradasi keandalan struktur terhadap variasi umur kelelahan dengan target level keandalan untuk fatigue = 2. Dengan variasi tegangan ekstrem mencapai 550 Mpa, didapatkan bahwa struktur mencapai tahap kritisnya saat umur kelelahan struktur mencapai 72 tahun. Maka dapat dikatakan bahwa struktur aman karena fatigue life> 2 x service life.
============================================================
The impact of environmental random (wave) load can effect the structure's behavior of jack up platform. With the increasing of operation time of a structure, it surely will need reliability analysis to its fatigue in order to have safety index. In this case we use random variable from operational load due to wave load that affect the analysis of fatigue life by considering the stress range during operation time. The simplification in this method is done using mathematical probability by first determining random variable as the load factor and resistance factor. Structure that will be analyzed is Jack-up Hang Tuah MOgPU platform owned by Conoco Indonesia INC.LTD. The natural period of this structure is 3,25 seconds, so it is recommended to use spectral fatigue analysis in the analysis of fatigue life due to cyclic wave during operation, as recommended in API RP-2A WSD 21. Probability Distribution used for fatigue life analysis are Rayleigh Distribution and Weibull distribution. From the result of spectral fatigue analysis by using Closed Form Fatigue equation is around 86 years with reliability index about 3,14 as the initial condition, for service life 25 years where the critical joint is D7523 with its member TD6929. For reliability analysis, the method
that I used is Advanced First Order Second Moment (AFOSM). For this matter we will need the graphic of reliability degradation with level reliability for fatigue = 2. By using the variation extreme stress until 550 Mpa, we can get the result the structure reached critical point when the fatigue life is 72 years. And the value of reliability index for service life 25 years = 3,92. So, we can conclude that the structure is safe because the fatigue life>2 x service life
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSKe 627.98 Far a |
Uncontrolled Keywords: | spectral fatigue analysis, closed form fatigue equation, AFOSM, indeks keandalan, spectral fatigue analysis, closed form fatigue equation, AFOSM, reliability index |
Subjects: | T Technology > TC Hydraulic engineering. Ocean engineering > TC1680 Offshore structures |
Divisions: | Faculty of Marine Technology (MARTECH) > Ocean Engineering > 38201-(S1) Undergraduate Thesis |
Depositing User: | ansi aflacha |
Date Deposited: | 04 Apr 2018 03:38 |
Last Modified: | 04 Apr 2018 03:38 |
URI: | http://repository.its.ac.id/id/eprint/51684 |