Pengaruh Karakteristik Penghuni Apartemen Terhadap Kualitas Udara Dalam Unit Apartmen Untuk Parameter Karbon Monoksida dan Nitrogen Dioksida

Pradana, Alfendha Wiranditya (2018) Pengaruh Karakteristik Penghuni Apartemen Terhadap Kualitas Udara Dalam Unit Apartmen Untuk Parameter Karbon Monoksida dan Nitrogen Dioksida. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03211440000050-UNDERGRADUATE-THESES.pdf]
Preview
Text
03211440000050-UNDERGRADUATE-THESES.pdf - Accepted Version

Download (2MB) | Preview

Abstract

Polusi udara di dalam ruangan menjadi masalah kesehatan yang lebih serius dibanding masalah kesehatan di luar ruangan. Masalah ini disebabkan sebagian besar waktu dihabiskan pada ruangan dengan kondisi lebih tertutup sehingga bahan pencemar tidak dapat mengalir bebas melainkan terakumulasi di dalam ruangan. Salah satu pencemar udara didalam ruangan yaitu nitrogen dioksida (NO2) dan karbon monoksida (CO). Kualitas udara ruang yang tidak memenuhi persyaratan baku mutu dapat menimbulkan dampak kesehatan. Penelitian ini bertujuan untuk mengevaluasi kualitas udara dalam ruang pada parameter CO dan NO2 dengan baku mutu dan mengevaluasi aktivitas dan perabotan penghuni yang akan mempengaruhi kualitas udara ruang pada parameter CO dan NO2.
Penelitian ini secara keseluruhan dilakukan di 40 unit apartemen. Evaluasi yang digunakan untuk menganalisis hasil kualitas udara dalam ruang yaitu membandingkan hasil pengukuran dengan baku mutu Permenkes RI NO.1077 tahun 2011. Hasil pengukuran CO dan NO2 dibandingkan dengan baku mutu yang telah dikonversi. Hasil analisis dengan baku mutu digunakan untuk mengetahui tingkat pencemaran udara ruang di tiap unit apartemen. Selain itu, nilai dari konsentrasi CO dan NO2 digunakan untuk menganalisis pengaruh aktivitas penghuni dan objek yang berada dalam ruangan apartemen tersebut seperti waktu membuka jendela, jumlah AC, waktu memasak, jumlah exhaust fan, jumlah kipas angin, jumlah kamar, waktu membersihkan unit apartemen, suhu dan kelembaban. Metode yang digunakan yaitu metode regresi linier berganda yang didapatkan melalui aplikasi minitab dengan melakukan uji linieritas terlebih dahulu menggunakan aplikasi SPSS.
Berdasarkan hasil penelitian yang telah dibandingkan dengan baku mutu yang telah dikonversi, tidak terdapat unit apartemen yang melebihi baku mutu CO dan NO2. Hasil yang didapat pada 40 unit apartemen memiliki nilai konsentrasi CO yang tidak melebihi 39,3 mg/m3 dan nilai konsentrasi NO2 tidak melebihi 0,348 mg/m3 . Hasil analisis menunjukan konsentrasi CO dan NO2 dipengaruhi oleh kelembaban, suhu, jam buka jendela, jumlah AC, waktu memasak, jumlah exhaust fan dan jumah kipas angin karena nilai signifikansinya dibawah 0,05. Nilai R square yang didapat dari parameter CO adalah 37,8% dan parameter NO2 adalah 28,7%
======================================================================================================
Indoor air pollution become the most threat to health
compared to outdoor air pollution. Due the fact that most of the time
used in enclosed space, it becomes the reason that the air pollution
accumulates inside the space. Some of the indoor air pollutants are
nitrogen dioxide (NO2) and carbon monoxide (CO). The air quality
doesn’t meet the required standard which can cause an impact to
health. This research aimed to evaluate the air quality in enclosed
space with CO and NO2 as the parameter and evaluate the indoor
activities and home appliance of inhabitant which have an effect to
CO and NO2
Thid whole research is done 40 apartment units.
Evaluation used to analyze the result of indoor air quality is
comparing the result of measurement with quality standard of
Permenkes RI No 1077 year 2011. The measurement of CO and
NO2’s result is compared to the air quality that has been converted.
Those results are used to determine the level of air pollution in each
apartment units. In addition, the values of CO and NO2
concentrations are used to analyze the effect of occupant’s
acitivties and objects in the apartement room such as window
opening hours, number of air conditioners, cooking time, number
of exhaust fans, number of fans, number of rooms, the time to clean
the apartment unit, temperature, and humidity. The method used
is multiple linear regression method which obtained through the
Minitab application by firstly conducting linearity test using the
SPSS application.
iv
Based on the results of research that has been compared
with the converted quality standards, there are no apartment units
that exceed the quality standards of CO and NO2. The results
obtained are in 40 apartment units have a CO concentration value
not exceeding 39.3 mg / m3 and NO2 concentration value does not
exceed 0.348 mg / m3
. The results of the analysis showed that CO
and NO2 concentrations were affected by humidity, temperature,
window opening hours, number of air conditioners, cooking time,
number of exhaust fans, and the number of fans because the
significance value was below 0.05. The R square value obtained
from the CO parameter is 37.8% and the NO2 parameter is 28.7%.

Item Type: Thesis (Undergraduate)
Additional Information: RSL 628.53 Pra p-1
Uncontrolled Keywords: Nitrogen dioksida (NO2), Karbon monoksida (CO), model regresi linier berganda.
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD883 Air quality management.
T Technology > TD Environmental technology. Sanitary engineering > TD883.5 Air--Pollution