Analisis Karakteristik Aliran Pada Area Tip Clearance Dan Blade Cascade Serta Pengaruhnya Terhadap Performa Kompressor Aksial

Mala, Fatmawati (2018) Analisis Karakteristik Aliran Pada Area Tip Clearance Dan Blade Cascade Serta Pengaruhnya Terhadap Performa Kompressor Aksial. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02311440000092-Undergraduated_Theses.pdf]
Preview
Text
02311440000092-Undergraduated_Theses.pdf - Accepted Version

Download (2MB) | Preview

Abstract

Pada tugas akhir ini dilakukan analisis aliran 3D pada area tip clearance dan blade cascade. Tip clearance merupakan salah satu penyebab loss yang dapat mengganggu performa kompresor aksial. Simulasi pada tugas akhir ini dilakukan dengan menggunakan dua blade twist dengan panjang chord 80 mm, span 100 mm dan variasi tip clearance sebesar 1mm, 2mm dan 4 mm. Karakteristik aliran yang terjadi berdasarkan hasil simulasi meliputi fenomena aliran vortex dan aliran terseparasi. Pada area near hub dengan sudut stagger 15o terbentuk aliran terseparasi dari leading edge yang menyebabkan tekanan di sekitar sisi cekung blade menjadi kecil, yaitu 500 Pa (tekanan relatif). Pada area mid span dengan sudut stagger 42 o terbentuk aliran vortex yang luas, menyebabkan area low pressure pada sisi cekung semakin luas. Pada area near tip dengan sudut stagger 61 o terbentuk aliran terseparasi dari titik nodal, aliran ini juga menyebabkan terbentuknya area bertekanan rendah yang luas pada sisi cekung. Peningkatan nilai tip clearance berdampak pada intensitas aliran vortex yang semakin besar. Pada tip clearance 4 mm daerah dengan vorticity 0.5 meliputi area yang luas di belakang trailing edge. Aliran vortex dapat menyebabkan terjadinya blockage effect . Oleh karena itu, pemberian tip clearance lebih besar dari 3% span tidak direkomendasikan.
=========================================================
This final project analyzes 3D flow that occurs on tip clearance and blade cascade area. Tip clearance is the cause of disturbance on an axial flow compressor. In this final project, simulation was performed using two rotary blade with dimention ; 80 mm chord length and 100 mm span length. The variation of tip clearance is ; 1mm, 2mm and 4 mm. Simulation result indicate that characteristics of the flow is vortex and separation. In the near hub with a staggered angle of 15o, the streams furred from the leading edge cause a low pressure region on the concave side area, the pressure is 500 Pa (relative pressure). In the mid span with a staggered angle 42o formed a vortex flow that very broad, lead the low pressure in this area become wider . In the near tip with a staggered angle 61o formed a steady stream from nodal point on the concave side of the blade, this stream also lead the low pressure in this area. In 4 mm tip clearance, vortex region extends to the rear trailing edge. Vortex flow can makes blockage effect. Therefore, tip clearance which is over than 3% span is not recommended.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: tip clearance , blade cascade , vortex, separasi aliran. ========================================================= tip clearance , blade cascade , vortex, separation flow
Subjects: Q Science > QC Physics
T Technology > TJ Mechanical engineering and machinery
T Technology > TJ Mechanical engineering and machinery > TJ990 Compressors
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis