Studi Pengaruh Drop Panel Dan Shear Cap Terhadap Kekuatan Geser Dan Lendutan Flat Slab Pada Gedung Hotel Swiss-Belinn Surabaya

Pradipto, Nindyonawi (2018) Studi Pengaruh Drop Panel Dan Shear Cap Terhadap Kekuatan Geser Dan Lendutan Flat Slab Pada Gedung Hotel Swiss-Belinn Surabaya. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3114100106-Undergraduate_Theses.pdf] Text
3114100106-Undergraduate_Theses.pdf
Restricted to Registered users only

Download (16MB) | Request a copy

Abstract

Di berbagai kota besar bangunan tinggi sangat dibutuhkan oleh manusia. Semakin minim lahan yang tersedia menjadi salah satu pemicu sangat dibutuhkannya pembangunan gedung secara vertical. Sistem struktur bangunan tinggi harus dapat memikul beban gravitasi dan juga beban gempa sesuai dengan lokasi bangunan tinggi tersebut. Selain kuat memikul beban, bangunan tinggi juga harus mampu memberikan kenyamanan kepada penghuninya. Maka dari itu para ahli struktur mulai mengembangkan suatu sistem struktur baru yang mampu memberikan ruang yang luas tanpa mengurangi keamanan struktur gedung tersebut dalam menerima beban gravitasi maupun beban gempa. Sistem struktur tersebut adalah flat slab. Metode flat slab terbukti baik untuk menerima beban gravitasi, sedangkan untuk menerima beban lateral (gempa) belum terbukti ketepatan dan keakuratanya . Ada berbagai macam metode yang bisa digunakan sebagai perkuatan flat slab, diantaranya adalah drop panel dan shear cap. Perhitungan dari kedua metode tersebut sudah diatur dalam SNI 2847 2013 dan ACI 318 M14. Namun dalam peraturan tersebut tidak dijelaskan secara mendetail tentang perbedaan fungsi dari drop panel dan shear cap. Dalam ACI 318 M14 pasal 8.2.4 dijelaskan bahwa drop panel dapat mengurangi ketebalan pelat lantai dan juga mengurangi kebutuhan penulangan momen negatif. Sementara itu pada ACI 318 M14 pasal 8.2.5 shear cap dapat menambah kekuatan geser di daerah kritis pada sambungan pelat lantai dan kolom. Pada tugas akhir ini penulis akan membandingkan pengaruh shear cap dan drop panel terhadap kekuatan geser dan lendutan dari flat slab pada Gedung Hotel Swiss-Belinn yang difungsikan sebagai hunian vertical di daerah Tegalsari, Surabaya, Jawa Timur. Dari hasil analisa yang dilakukan, dapat disimpulkan bahwa drop panel maupun shear cap mampu mengurangi lendutan di flat slab dan juga tegangan geser di daerah kritis sekitar kolom. Namun, drop panel lebih efektif untuk mengurangi lendutan pada flat slab, sedangkan shear cap lebih efektif untuk mengurangi tegangan geser di daerah kritis sekitar kolom.
===============================================================================================================================
In many cities, multi-storey buildings are needed for humans. The scarcity of land availability and the increasing land prices, thus allowing for the construction of vertical buildings. High structural building systems must be able to bear the burden of gravity and earthquake shocks based on their location. Building model not only having strong structural strength but also able to provide luxury to its consumer. Therefore, construction experts develop a structural system called flat slab. The flat slab method itself proved good for receiving gravitational loads, while for receiving lateral loads (earthquakes) has not been proven. There are various methods that can be used as flat slab strengthening, including drop panel and shear cap. Calculations of both methods are set forth in SNI 2847 2013 and ACI 318 M14. But the regulation does not explain in detail about the different functions of the drop panel and shear cap. In ACI 318 M14 section 8.2.4 it is explained that drop panels can reduce the thickness of floor plates and also reduce the need for negative moment reinforcement. Meanwhile, the ACI 318 M14 section 8.2.5 shear cap can increase the shear strength in critical areas in the connection of floor plates and column. Therefore, in this final project writer tried to compare the influence of shear cap and drop panel on the shear strength and deflection of flat slab at Swiss-Belinn Hotel Building which functioned as vertical residence in Tegalsari, Surabaya, East Java. From the analysis conducted, it can be concluded that the drop panel and shear cap can reduce the deflection on the flat slab and also the shear stress in the area around the column. However, drop panels are more effective at reducing deflections on flat slabs, while shear caps are more effective at reducing shear stress in critical areas around the columns.

Item Type: Thesis (Other)
Uncontrolled Keywords: Reinforced Concrete, Flat Slab, Drop Panel, Shear Cap
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TA Engineering (General). Civil engineering (General) > TA681 Concrete construction
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Nindyonawi Pradipto
Date Deposited: 16 Jul 2024 04:25
Last Modified: 16 Jul 2024 04:25
URI: http://repository.its.ac.id/id/eprint/57045

Actions (login required)

View Item View Item