Rancang Bangun Sistem Pengendalian Temperature Pada Tangki Pendingin Melalui Manipulasi Laju Aliran Refirgrant Dengan Menggunakan Refrigrant R-22 Pada Mini Plant Heat Exchanger Type Shell And Tube Sebagai Alat Uji Kompetensi

Apanto, Akhmad Aris (2018) Rancang Bangun Sistem Pengendalian Temperature Pada Tangki Pendingin Melalui Manipulasi Laju Aliran Refirgrant Dengan Menggunakan Refrigrant R-22 Pada Mini Plant Heat Exchanger Type Shell And Tube Sebagai Alat Uji Kompetensi. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of LAPORAN TUGAS AKHIR.pdf]
Preview
Text
LAPORAN TUGAS AKHIR.pdf - Accepted Version

Download (2MB) | Preview

Abstract

Dispenser merupakan salah satu alat yang membutuhkan listrik untuk dapat menjalankan sistem pemanasan sekaligus sistem pendinginan kemudian air conditioner (AC) merupakan sebuah alat yang mampu mengkondisikan udara dengan kata lain air conditioner (AC) berfungsi sebagai penyejuk udara pada ruangan.
Pada tugas akhir ini akan dilakukan perancangan dan pembuatan sistem pengendalian temperatur air yang dapat dijalankan secara otomatis pada proses pengendalian secara manual dengan penekanan tombol pada dispenser dipasaran akan dimodifikasi dengan cara menggunakan aktuator berupa selenoid valve sebagai pengendali aliran air dan sensor float switch untuk menjaga kesetabilan volume air sesuai dengan kapasitas kemudian sensor thermocoupel yang digunakan untuk menjaga suhu air sesuai dengan setpoint yang telah di tentukan yaitu up to 10℃.
Hasil yang didapatkan pada proses perancangan alat tugas akhir ini yaitu pendinginan air dari suhu normal yang mana rata –rata yaitu 25 - 30 °C di dinginkan pada tangki pendingin dan dapat mencapai setpoint 10 °C dengan lamanya proses pendinginan selama 12 menit dengan volume air 50 liter. Menggunakan sistem Air Conditioner (AC) 2 PK = ±18.000 BTU/h.
=====================================================================================================
Dispenser is one of the tools that require electricity to be able to run the heating system as well as cooling system then air conditioner (AC) is a tool capable of conditioning air in other words air conditioner (AC) serves as air conditioning in the room.
In this final project will be design and manufacture of water temperature control system which can be executed automatically on the control process manually with keystrokes on the market dispenser will be modified by using actuator in the form of selenoid valve as water flow controller and float switch sensor to maintain the volume stability water in accordance with the capacity and then thermocoupel sensor used to maintain the water temperature in accordance with the setpoint that has been determined that is up to 10 ℃.
The results obtained in the design process of this final task tool is cooling water from normal temperature where the average is 25-30°C in cooled in the cooling tank and can reach setode 10 ° C with the duration of cooling process for 12 minutes with water volume 50 liter. Using air conditioner (AC) 2 PK = ± 18,000 BTU /h.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Dispenser, Refrigrant, Air Conditioning (AC); Dispenser, Refrigrant, Air Conditioning (AC)
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Vocational > Instrumentation Engineering
Depositing User: Akhmad Aris Apanto
Date Deposited: 19 Jun 2021 15:36
Last Modified: 22 Jun 2021 08:12
URI: http://repository.its.ac.id/id/eprint/58223