Tugas akhir ini berisikan penelitian untuk mendapatkan peralatan
tes surja yang memiliki akurasi tinggi dan memenuhi standar. Untuk
mendapatkan peralatan tersebut, maka pada penelitian ini akan
dilakukan pengujian variasi komponen pada peralatan tes surja. Nilainilai
komponen yang ada pada peralatan tes surja tersebut akan
divariasikan dan diujikan pada beberapa belitan motor induksi dengan
kondisi yang berbeda-beda. Lalu hasil tersebut akan dianalisis
menggunakan metode error area ratio dan dibandingkan dengan
standar. Setelah dilakukan pengujian ternyata didapatkan hasil bahwa
nilai-nilai komponen pada peralatan tes surja memiliki dampak yang
cukup besar terhadap hasil pengujian. Contohnya pada pengujian dengan
variasi tegangan uji, semakin besar tegangan uji yang digunakan maka
kerusakan isolasi antar belitan semakin mudah terdeteksi. Selain itu dari
penelitian ini juga didapatkan nilai-nilai komponen yang paling ideal
untuk memenuhi standar yang ada.
=======================================================================================================
This final project contains a research to get a surge test equipment
that has high accuracy and fulfill the standards. To get it, so this research
will be testing components on the surge test equipment with varying
component values. The values of the components on the surge test
equipment will be varied and tested in several induction motor winding
with different conditions. Then the results will be analyzed using the
error area ratio method and compared to a standard. After testing it was
found that the results of the component values in the surge test
equipment have big impact on the results of testing. For example in the
test with a test voltage variation, the greater value of the test voltage
make the turn to turn insulation fault more easily detected. Besides from
this research also found the component values that most ideal to fulfill
the standards.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.313 6 Nug d
Uncontrolled Keywords: Kegagalan isolasi antar belitan, metode error area ratio, pengaruh komponen pada peralatan, pengujian dengan variasi nilai komponen, tes surja.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2785 Electric motors, Induction.
Divisions: Faculty of Electrical Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 22 Jan 2019 04:17
Last Modified: 22 Jan 2019 04:17
URI: http://repository.its.ac.id/id/eprint/60369

Actions (login required)

View Item View Item