Desain Perkuatan Struktur Gedung Apartemen Di Waru Sidoarjo Menggunakan Carbon Fiber Reinforced Polymer (CFRP) Akibat Alih Fungsi Atap Menjadi Skygarden

Jidni, Mohamad Agus (2019) Desain Perkuatan Struktur Gedung Apartemen Di Waru Sidoarjo Menggunakan Carbon Fiber Reinforced Polymer (CFRP) Akibat Alih Fungsi Atap Menjadi Skygarden. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10111510000055-MOHAMAD AGUS JIDNI-UNDERGRADUATE THESIS.pdf] Text
10111510000055-MOHAMAD AGUS JIDNI-UNDERGRADUATE THESIS.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2023.

Download (39MB) | Request a copy

Abstract

Tugas Akhir Terapan ini mengambil studi kasus pada salah satu Bangunan gedung apartemen. Gedung apartemen yang digunakan terletak di Sidoarjo. Bangunan ini terdiri dari 12 lantai dan 1 lantai atap deck beton. Untuk meningkatkan fasilitas apartemen, atap deck beton tersebut akan dialih fungsikan menjadi skygarden. Alih fungsi atap menjadi skygarden ini menyebabkan perubahan beban hidup dari 0,96 kN/m2 menjadi 4,79 kN/m2.
Akibat alih fungsi ini, studi memperkirakan perlunya perkuatan struktur pada bangunan eksisting. Oleh karena itu, gedung apartemen dianalisa untuk mengetahui kinerja struktur bangunan. Dalam analisa ini menggunakan beberapa peraturan terkait seperti : SNI 2847 -2013 “Persyaratan Beton Struktural untuk Gedung”, SNI 1727-2013 “Beban minimum untuk perancangan bangunan gedung dan struktur lain)”, dan SNI 1726-2012 “Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan non gedung”. Tugas Akhir Terapan ini menggunakan teknologi CFRP sebagai perkuatan struktur. CFRP dipilih karena dalam pelaksanaannya CFRP lebih mudah dilakukan di lapangan. Selain itu, pemasangan CFRP dikerjakan dengan tidak membongkar elemen struktur eksisting. Hal tersebut berdampak pada pengerjaan konstruksi yang lebih cepat. CFRP yang digunakan adalah CFRP yang diproduksi oleh SIKA. Perencanaan CFRP mengikuti peraturan yang berlaku yaitu ACI 440.2R-17 “Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures.”
Setelah dilakukan analisa, pada elemen struktur sekunder (balok anak, pelat dan tangga) masih mampu menahan beban yang terjadi, sedangkan pada elemen struktur primer terdapat 30 balok yang memerlukan perkuatan lentur dan 20 balok yang memerlukan perkuatan geser. Sedangkan pada kolom, shear wall dan pondasi masih dapat memikul beban yang terjadi.
================================================================================================
This Applied Final Project takes a case study on one of
the apartment buildings. This building is located at Sidoarjo. The
building is 12 floors high and has a roof constructed using
concrete deck. To improve the apartment’s facility, the concrete
floor will be converted into a Skygarden. The conversion will
have an impact to the life load from 0.96 kN/m2 to 4.79 kN/ m2.
As a result of this conversion, the study estimates that it
need strengthening structures in existing buildings. Therefore,
apartment buildings are analyzed to find out the performance of
building structures. In this study use several codes such as : SNI
2847 -2013 “Persyaratan Beton Struktural untuk Gedung”, SNI
1727-2013 “Beban minimum untuk perancangan bangunan
gedung dan struktur lain)”, and SNI 1726-2012 “Tata cara
perencanaan ketahanan gempa untuk struktur bangunan gedung
dan non gedung”. This Applied Final Project use the CFRP
technology as the strengthening structures. Its execution because
CFRP is easier to utilize in the field. Other than that, the
application of CFRP was worked without removing the existing
element structure. It impact to a quicker construction process.
CFRP that was used was the one produced by SIKA. Design of
CFRP follow the codes regarded currently, ACI 440.2R-17
“Guide for the Design and Construction of Externally Bonded
FRP Systems for Strengthening Concrete Structures.”
After the analysis was done, the secondary structural
element (joist, plate, and stairwells) was still able to hold the
pressure. Meanwhile, within the primary structural element there
were 30 beams that are in need of more bending strengthening
and 20 beams in need of shear strengthening, and in the columns,
shear wall and fondation were still able to endure the pressure
output.

Item Type: Thesis (Undergraduate)
Additional Information: RSIS 624.183 414 Jid d-1 2019
Uncontrolled Keywords: CFRP, Perkuatan, Skygarden, Strengthening
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
T Technology > TA Engineering (General). Civil engineering (General) > TA681 Concrete construction
Divisions: Faculty of Vocational > Civil Infrastructure Engineering (D4)
Depositing User: Jidni Mohamad Agus
Date Deposited: 06 Oct 2021 03:26
Last Modified: 06 Oct 2021 03:26
URI: http://repository.its.ac.id/id/eprint/61327

Actions (login required)