Fadilah, Titin Nur (2019) Sistem Monitoring Tegangan, Arus, dan Frekuensi Keluaran Generator pada Modul Mini Power Plant. Diploma thesis, Institut Teknologi Sepuluh Nopember.
|
Text
10511600000037-Undergraduate_Thesis.pdf Restricted to Repository staff only Download (2MB) | Request a copy |
Abstract
Tenaga listrik sudah menjadi suatu kebutuhan dan kestabilan pada sistem tenaga listrik menjadi hal yang harus diperhatikan, salah satu pembangkit listrik yang sering digunakan adalah generator. Generator memiliki variabel-variabel fisis yang harus dijaga kestabilannya antara lain tegangan, arus dan frekuensi. Sehingga untuk mengetahui besar tegangan dan arus yang dihasilkan oleh generator maka dibuatlah alat yang dapat mengukur besar arus, tegangan dan frekuensi yang dihasilkan oleh generator yaitu sistem monitoring. Pada sistem monitoring keluaran generator digunakan sensor tegangan ZMPT101B untu mengukur tegangan keluaran generator. Untuk mengukur besar arus menggunakan sensor ACS712 dan untuk mengukur frekuensi menggunakan zero crossing detector. Dari data uji sistem monitoring didapat hasil yaitu sensor tegangan ZMPT101B yang memiliki pembacaan error sebesar 0,01 untuk error pembacaan sensor ACS712 sebesar 0,09 dan untuk error pembacaan sensor frekuensi sebesar 0,01. Kesimpulannya ketiga sensor ini berhasil digunakan dalam sistem monitoring tegangan, arus dan frekuensi keluaran generator.
===========================================================================================================================
Electric power has become a necessity and the stability of the electric power system has to be considered, one of the power plant that are often used is a generator. The generator has physical variables which must be maintained, including voltage, current and frequency. So to find out the voltage and current produced by the generator, a device can be used to measure the voltage, current and frequency generated by the generator, namely the monitoring system. The generator output monitoring system uses the ZMPT101B voltage sensor to measure the generator output voltage. To measure the current using an ACS712 sensor and to measure the frequency using a zero crossing detector. From the monitoring system test data the results obtained are ZMPT101B voltage sensors that have an error reading of 0,01 for ACS712 sensor reading errors of 0,09 and for frequency sensor reading errors of 0,01. In conclusion, the three sensors are successfully used in monitoring the voltage, current and generator output frequency systems.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Generator, ZMPT101B Voltage Sensor, ACS712 Current Sensor, Frequency Sensor. Generator, Sensor Tegangan ZMPT101B, Sensor Arus ACS712, Sensor Frekuensi. |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1322.6 Electric power-plants |