Modifikasi Perancangan Struktur Gedung Perkantoran Capital Square Surabaya Dengan Menggunakan Metode Flat Plate Dan Shear Wall

Timony, Robert Scott Aryan (2019) Modifikasi Perancangan Struktur Gedung Perkantoran Capital Square Surabaya Dengan Menggunakan Metode Flat Plate Dan Shear Wall. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111540000151-Undergraduate_Theses.pdf]
Preview
Text
03111540000151-Undergraduate_Theses.pdf

Download (9MB) | Preview

Abstract

Gedung Perkantoran eksisting Capital Square Surabaya merupakan gedung 35 lantai yang dibangun di Kota Surabaya yang termasuk dalam kategori risiko gempa menengah. Bangunan gedung tersebut akan dimodifikasi dengan menggunakan metode flat plate dan shear wall. Dalam tugas akhir ini, dilakukan beberapa modifikasi perencanaan. Modifikasi yang dilakukan diantaranya adalah mengurangi jumlah lantai menjadi 15 lantai dengan menggunakan sistem flat plate dikombinasikan dengan shear wall yang berfungsi sebagai struktur penahan gaya lateral. Struktur atas lainnya meliputi kolom dan balok tepi. Struktur bawah direncanakan menggunakan pondasi tiang pancang dengan pile cap. Gedung akan dimodelkan secara tiga dimensi dengan pembebanan gravitasi dan gempa. Dilakukan analisis mengenai besaran base shear dan story drift untuk memenuhi aspek keamanan gedung.
Sistem flat plate digunakan secara luas pada bangunan gedung karena beberapa kelebihan dalam aspek struktural maupun arsitektural. Dibandingkan dengan sistem rangka pemikul momen pada umumnya, struktur yang menggunakan sistem flat plate memiliki jumlah lantai lebih banyak dengan tinggi gedung yang sama dikarenakan tidak menggunakan balok interior sehingga mengurangi tinggi tiap lantai. Selain itu waktu konstruksi menjadi lebih singkat serta biaya konstruksi menjadi lebih murah dikarenakan tidak diperlukan pekerjaan pembuatan bekisting, penulangan, serta pengecoran elemen balok interior.
Dalam tugas akhir ini, secara keseluruhan struktur direncanakan dengan sistem rangka gedung. Jika direncanakan menggunakan dinding geser beton bertulang khusus, kategori desain seismik yang sesuai adalah B dan C tidak dibatasi, D dan E dibatasi dengan ketinggian maksimum 48m, serta F dibatasi dengan ketinggian maksimum 30m.
Berdasarkan hasil analisis yang telah dilakukan didapatkan ringkasan bahwa rangka utama Gedung mampu menahan beban lateral arah X dan arah Y dengan besar simpangan pada lantai atap sebesar 20,173 mm dengan periode struktur sebesar 0,639 detik. Ketebalan flat plate yang direncanakan adalah 250 mm dan ketebalan shear wall yang direncanakan adalah 400 mm.
===============================================================================================================================
The exsisting Capital Square Surabaya Office is a 35-story building to be constructed in Surabaya which is located in intermediate earthquake zone. The office building will be modified using Flat Plate and Shear Wall. On this final project, there are several structural design modifications that will be done. One of which are reducing the amount of stories available to just 15-stories using Flat Plate system combined with Shear Wall to provide adequate resistance against lateral earthquake forces. The other main structure elements to be designed are columns and perimeter beams. For the foundation design, spun piles with pile cap will be used. The 3-Dimensional model of the building will be made. This model is designed to withstand any gravity and earthquake loadings. Therefore, the model will be analyzed to obtain structure response results such as base shear and story drift to fulfill the structureal security aspects.
The flat plate system is widely used in buildings because of several advantages in structural and architectural aspects. Compared to the frame resisting moment system in general, the structure that uses a flat plate system has a higher number of floors with the same building height because it does not use interior beams thereby reducing the height of each floor. In addition, construction time will be shorter and construction costs will be cheaper because it is not required to make formwork, reinforcement and concrete casting of beam elements.
In this final project, the overall structure is designed using building frame system. If it is planned using specially reinforced concrete shear walls, the seismic design category for maximum building height which is suitable are, B and C are not restricted, D and E are resricted to maximum height of 48 meters, while F is restricted to maximum height if 30 meters.
Based on the results of the analysis that has been done, it is obtained a summary that the main frame of the building is able to withstand lateral loads in the direction of X and direction of Y with structural displacement on the roof floor about 20,173 mm with a period of structure about 0.639 seconds. The designed flat plate thickness is about 250 mm and as for the shear wall thickness is about 400 mm

Item Type: Thesis (Other)
Uncontrolled Keywords: Flat Plate, Shear Wall, Gempa
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
T Technology > TH Building construction > TH3000 Basements--Remodeling.
Divisions: Faculty of Civil, Environmental, and Geo Engineering > Civil Engineering > 22201-(S1) Undergraduate Theses
Depositing User: Robert Scott Aryan Timony
Date Deposited: 09 Jul 2024 03:01
Last Modified: 09 Jul 2024 03:01
URI: http://repository.its.ac.id/id/eprint/66351

Actions (login required)

View Item View Item