Simulasi Pengaruh Kondisi Operasi Hph Off Service terhadap Performa Pltu dan Optimasi Tekanan Ekstraksi Hph menggunakan Software Cycle Tempo

Ramadhanti, Narumi Dwi (2019) Simulasi Pengaruh Kondisi Operasi Hph Off Service terhadap Performa Pltu dan Optimasi Tekanan Ekstraksi Hph menggunakan Software Cycle Tempo. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111540000034_Undergraduate_Thesis.pdf] Text
02111540000034_Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (6MB) | Request a copy

Abstract

High Pressure Heater (HPH) berfungsi meningkatkan temperatur air yang akan dipanaskan di dalam boiler sehingga penggunaan bahan bakar lebih sedikit. HPH sering menghadapi masalah sehingga harus dilakukan perbaikan, yang mengharuskan HPH dalam kondisi off service. Kondisi tersebut memengaruhi daya netto, net plant heat rate, dan efisiensi sistem pembangkit. Pada PLTU PT.PJB UBJOM Paiton Unit 9, apabila salah satu HPH mengalami kerusakan maka seluruh HPH tidak beroperasi karena by pass dipasang dari deaerator langsung menuju ke boiler. Oleh karena itu, dilakukan studi lebih lanjut mengenai pengaruh kondisi off service HPH terhadap performa pembangkit. Analisis dilakukan pada software Cycle Tempo 5.0 dan menggunakan data operasi aktual. Setelah itu memvariasikan simulasi dengan mengatur kondisi operasi HPH, dilakukan dengan mengatur bukaan valve yang masuk ke sisi tube HPH. Selanjutnya dilakukan variasi tekanan uap ekstraksi HPH yang masih beroperasi agar didapatkan performa pembangkit optimum. Hasil penelitian dari variasi kondisi HPH off service yaitu kondisi yang paling optimal adalah kondisi eksisting dengan nilai NPHR terendah yaitu 2452,047 kCal/kWh dan nilai efisiensi sistem tertinggi yaitu 35,236%. Variasi yang paling merugikan adalah variasi HPH 1,2,3 off dengan nilai NPHR terbesar yaitu 2513,818 kCal/kWh dan nilai efisiensi sistem terendah yaitu 34,37%. Dari hasil perhitungan kecepatan fluida di dalam pipa dan beban pemanasan HPH didapatkan hasil bahwa pada variasi kondisi HPH 2 off, HPH 3 off, HPH 2 dan HPH 3 off, serta HPH 1 dan HPH 3 off , terdapat kecepatan fluida ekstraksi ke HPH melebihi kecepatan desain dan beban pemanasan HPH melebihi beban pemanasan maksimum. Hal ini karena laju massa uap ekstraksi ke HPH bertambah secara signifikan. Selanjutnya dilakukan variasi tekanan uap ekstraksi pada HPH. Saat HPH 1 off , tekanan uap ekstraksi 30 bar untuk HPH 2 dan tekanan uap ekstraksi 18 bar untuk HPH 3. Saat HPH 2 off , tekanan uap ekstraksi 45 bar untuk HPH 1 dan tekanan uap ekstraksi 24 bar untuk HPH 3. Saat HPH 3 off , tekanan uap ekstraksi 50 bar dengan TTD 15֯C untuk HPH 1 dan tekanan uap ekstraksi 30 bar dengan TTD 20֯C untuk HPH 2. Saat HPH 1 dan HPH 2 off, tekanan uap ekstraksi 22 bar untuk HPH 3. Saat HPH 2 dan HPH 3 off, tekanan uap ekstraksi 40 bar TTD 33֯C untuk HPH 1. Saat HPH 1 dan HPH 3 off, tekanan uap ekstraksi 35 bar TTD 20֯C.
=====================================================================================================================================
The function of High Pressure Heater (HPH) is to increase the temperature of feedwater so the use of fuel will be decrease. HPH is often meets problems so HPH must be repaired (off-service condition). Thats affect net power, net plant heat rate, and efficiency of generating system. In PT.PJB UBJOM Paiton PLTU Unit 9, when a HPH is in damage then all of HPH will not be operated because by-pass system installed from deaerator goes directly to the boiler. Therefore, further studies were conducted on the effect of HPH off service conditions. The analysis was carried out using Cycle Tempo 5.0 software and use actual data. After that, vary the simulation by adjusting the operating conditions of HPH, it is done by adjusting valve openings on the tube side. Furthermore, variations in pressure of the extraction are carried out in order to obtain the optimum performance. The results from off-service HPH variation condition, the most optimal condition is the existing condition with the lowest NPHR value of 2452,047 kCal / kWh and the highest system efficiency value is 35,236%. The most detrimental variation is the variation of HPH 1,2,3 off with the largest NPHR value of 2513,818 kCal / kWh and the lowest system efficiency value of 34,37%. Calculation of fluid velocity in the pipe and heating duty of HPH, the results showed that variations in HPH 2 off, HPH 3 off, HPH 2 3 off, and HPH 1 3 off, there are fluid velocity of extraction to HPH exceeded the design velocity and HPH heating duty exceeds the maximum. This is because the mass extraction to HPH increases significantly. Variations of extraction pressure was then carried out on HPH. When HPH 1 off, extraction pressure is 30 bar for HPH 2 and extraction pressure of HPH 3 is 18 bar. When HPH 2 off, pressure extraction is 45 bar for HPH 1 and extraction pressure of HPH is 24 bar. When HPH 3 off , pressure extraction is 50 bar with TTD 15֯ C for HPH 1 and pressure extraction of HPH 2 is 30 bar with TTD 20֯ C. When HPH 1 2 off, pressure extraction of HPH 3 is 22 bar. When HPH 2 3 off, pressure extraction of HPH 1 is 40 bar with TTD 33C. When HPH 1 3 off, pressure extraction is 35 bar with TTD 20֯ C.

Item Type: Thesis (Other)
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ164 Power plants--Design and construction
T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Narumi Dwi Ramadhanti
Date Deposited: 21 Jul 2026 08:34
Last Modified: 21 Jul 2026 08:34
URI: http://repository.its.ac.id/id/eprint/66534