Uman Putra, Novian Patria (2019) Pengaruh Harmonik Terhadap Kestabilan Tegangan Pada Sistem Distribusi Radial Satu Fasa. Masters thesis, Institut Teknologi Sepuluh Nopember.
|
Text
07111650012004-Master_Thesis.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
Sistem distribusi merupakan bagian dari sistem penyaluran daya listrik yang memiliki parameter dan karakteristik yang berbeda dengan sistem transmisi. Hal ini disebabkan sistem distribusi langsung terhubung dengan beban, jenis beban sendiri ada dua macam yaitu beban listrik linier dan beban listrik non-linier akan tetapi beban non-linier merupakan penyebab arus harmonisa pada sistem kelistrikan yang berpengaruh pada kualitas daya listrik dan kerusakan peralatan. Oleh karena itu, pada penelitian ini dilakukan perhitungan aliran daya konvensional yang dikombinasikan dengan analisa harmonisa untuk mengetahui besar dan penyebaran harmonisa dilihat dari rugi-rugi daya dan tegangan jatuh pada sistem kelistrikan sehingga dapat diketahui seberapa besar pengaruh dari harmonisa pada kestabilan tegangan suatu sistem pada kondisi tertentu dengan melihat hasil kurva P-V. Metode yang dikembangkan pada penelitian ini adalah dengan menggabungkan antara analisa aliran daya backward-forward sweep dengan metoda penambahan beban Continuous Power Flow (CPF) dengan secant predictor yang digunakan untuk melihat kestabilan tegangan yang digunakan pada sistem distribusi radial satu fasa sehingga didapatkan nilai THD harmonisa dan nilai lamda (faktor pengali beban sistem) yang berbanding dengan tegangan pada bus tertentu serta pada penelitian ini didapatkan pada bus 10 adalah bus yang memiliki sensitifitas lebih tinggi dengan nilai tegangan yang semula sebelum adanya harmonisa didapatkan nilai 0,8911 pu dan lamda sebesar 3,119 menjadi nilai tegangan sebesar 0,914 pu dan lamda mencapai titik maksimum yaitu 2,321 . Simulasi dilakukan dengan bantuan perangkat lunak MatLab dan dibandingkan dengan perangkat lunak ETAP dengan validasi nilai THD dengan error sebesar 2,86% pada bus 10.
=================================================================================================================================
The distribution system is part of the electrical power transmission system which has different parameters and characteristics with the transmission system. This is because the distribution system is directly connected to the load, the type of load itself there are two kinds of linear electricity load and non-linear electrical load will but the non-linear load is the cause of the current distortion in the electrical system that Power and malfunction of the equipment. Therefore, in this research carried out the calculation of conventional power flow combined with the analysis of distortion to know the large and the spread of distortion seen from the power loss and voltage collapse on the electrical system so it can be known how large the effect of harmonizing on the tension stability of a system in certain conditions by looking at results of P-V curve. The method developed in this study was to combine between the backward-forward sweep power flow analysis with the method of adding Continuous Power Flow (CPF) loads with a secant predictor used to view the voltage stability used in one phase radial distribution system so that obtained the value of THD distortion and lamda value (factor system load multiplier) that compared with the voltage on the particular bus and in this research obtained on bus 10 is the bus Have a higher sensitivity with the value of voltage originally before the distortion obtained 0.8911 PU and lamda value of 3.119 to be a voltage value of 0.914 Pu and Lamda reached the maximum point of 2.321. The simulation was done with the help of MatLab software and compared to ETAP software with the validation of THD value with error of 2.86% on bus 10.
| Item Type: | Thesis (Masters) |
|---|---|
| Uncontrolled Keywords: | linier, non-linier, aliran daya, harmonisa, backward-forward sweep, rugi-rugi daya, tegangan jatuh, CPF, lamda, THD |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1010 Electric power system stability. Electric filters, Passive. T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3226 Transients (Electricity). Electric power systems. Harmonics (Electric waves). |
| Divisions: | Faculty of Electrical Technology > Electrical Engineering > 20101-(S2) Master Thesis |
| Depositing User: | Putra Novian Patria Uman |
| Date Deposited: | 23 Jul 2026 07:08 |
| Last Modified: | 23 Jul 2026 07:08 |
| URI: | http://repository.its.ac.id/id/eprint/67244 |