Hafizah, Winaldha Erza Nur (2019) Rancang Bangun Alat Pengukur Kadar Gas Metana Dan Karbondioksida Pada Tabung Penampung Biogas Di Lipi Gunungkidul Yogyakarta. Diploma thesis, Institut eknologi Sepuluh Nopember.
|
Text
10311600010026-Non_Degree.pdf - Accepted Version Restricted to Repository staff only Download (5MB) | Request a copy |
Abstract
Salah satu upaya yang dilakukan oleh pemerintah maupun peternak sapi untuk mengurangi limbah kotoran ternak yang selalu mencemari lingkungan yaitu dengan mengolah limbah kotoran ternak menjadi biogas. Terdapat beberapa kandungan gas pada biogas, komposisi terbesar ialah metana (CH4), karbondioksida (CO2) dan dapat mengakibatkan korosi pada kompor ataupun mesin jika tidak diketahui kadar gas tersebut. Oleh karena itu untuk mempermudah pembacaan kadar gas yang dihasilkan oleh biogas, diperlukan suatu alat yang bersifat portable. Sehingga para peternak dapat mengetahui kadar gas yang dihasilkan dalam bentuk presentase (%). Alat ini menggunakan arduino sebagai mikrokontroler yang telah dilengkapi oleh program, sensor MQ-4 sebagai sensor gas metana dan sensor MG 811 sebagai sensor gas karbondioksida, serta dilengkapi valve untuk mengkontrol gas agar sesuai ambang batas. Ambang batas yang ditetapkan untuk gas metana tidak melebihi dari 60% dan gas karbondioksida tidak melebihi dari 40%. Pada hasil pengujian didapatkan untuk tingkat error gas metana diperoleh 0,6% - 0,7% dan karbondioksida diperoleh error sebesar 0,7% - 1%. Biogas yang telah terukur sesuai dengan ambang batas, akan dialirkan ke tabung penampungan, sehingga para peternak maupun peneliti LIPI dapat mengetahui kadar gas dalam biogas.
=================================================================================================================================
One of the efforts made by the government and cattle breeders is to reduce livestock waste that always pollutes the environment by processing manure into biogas. There is some gas content in biogas, the biggest composition is methane (CH4), carbon dioxide (CO2) and can cause corrosion of the stove or machine if the gas level is not known. Therefore to facilitate the reading of the gas produced by biogas, a portable device is needed. So that the farmers can find out the level of gas produced in the form of a percentage (%). This tool uses Arduino as a microcontroller that has been equipped by the program, MQ-4 sensor as a methane gas sensor and MG 811 sensor as a carbon dioxide gas sensor, and equipped with a valve to control the gas to match the threshold. The threshold set for methane gas does not exceed 60% and carbon dioxide gas does not exceed 40%. In the test results obtained for the error rate of methane gas ob-tained 0.6% - 0.7% and carbon dioxide obtained an error 0.7% - 1%. Bio-gas that has been measured in accordance with the threshold, will be channeled to the storage tube, so that farmers and LIPI researchers can find the gas content in biogas.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Pengukur kadar CH4 dan CO2 , LIPI Gunungkidul Yogyakarta |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7871.674 Detectors. Sensors |
| Divisions: | Faculty of Vocational > 36304-Automation Electronic Engineering |
| Depositing User: | Nur Hafizah Winaldha Erza |
| Date Deposited: | 11 Aug 2026 06:45 |
| Last Modified: | 11 Aug 2026 06:45 |
| URI: | http://repository.its.ac.id/id/eprint/67979 |
Actions (login required)
![]() |
View Item |