Hartati, Ayu Dian (2019) Rancang Bangun Ratio Control Sistem Untuk Mengatur Rasio Flow Rate Air Panas Dan Flow Rate Air Dingin Pada Plant Simulator Heat Exchanger. Diploma thesis, Institut Teknologi Sepuluh Nopember.
|
Text
10511600000025_Non_Degree.pdf - Accepted Version Restricted to Repository staff only Download (2MB) | Request a copy |
Abstract
Heat Exchanger terdiri atas beberapa jenis, salah satunya yakni direct contact atau dapat dikatakan dua fluida dengan temperature yang berbeda akan bercampur menjadi satu. Untuk menjadikan temperature pada heat exchanger jenis direct contact sesuai dengan yang diinginkan, maka diperlukan adanya pengaturan terhadap debit air yang akan bercampur. Adapun sensor yang digunakan untuk mendeteksi debit air yang akan bercampur adalah flowmeter, sensor yang digunakan untuk mendeteksi temperature adalah RTD PT 100 3 wire. Hasil pengujian pengambilan data untuk pencampuran dilakukan dengan memanipulasi salah satu fluida (air panas) dan menganggap konstan fluida lainnya (air dingin). Hasil yang didapatkan berupa debit air dengan eror sekitar 1,5% hingga 4,25%. Hal ini disebabkan oleh beberapa faktor eror yang mempengaruhi pengambilan data dan pemprosesan plant.
================================================================================================================================
Heat Exchanger consists of several types, one of which is direct contact or it can be said that two fluids with different temperatures will mix into one. To make temperature in a direct contact heat exchanger as desired, it is necessary to regulate the water discharge that will mix. The sensor used to detect water discharge that will mix is a flow meter, the sensor used to detect temperature is RTD PT 100 3 wire. The test results of data collection for mixing are done by manipulating one fluid (hot water) and assuming the other fluid constant (cold water). The results obtained in the form of water discharge with an error of about 1.5% to 4.25%. This is caused by several error factors that affect data retrieval and processing of plants.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Heat Exchanger¸ Direct Contact, Flowmeter Sensor |
| Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers |
| Divisions: | Faculty of Vocational > Instrumentation Engineering |
| Depositing User: | HARTATI AYU DIAN |
| Date Deposited: | 14 Aug 2026 07:04 |
| Last Modified: | 14 Aug 2026 07:04 |
| URI: | http://repository.its.ac.id/id/eprint/70085 |
Actions (login required)
![]() |
View Item |