Rahma, Alifia Miftakhur (2019) Sistem Monitoring Variabel Voltage, Current, Dan Frequency Input Transformator Pada Modul Simulasi Mini Power Plant. Diploma thesis, Institut Teknologi Sepuluh Nopember.
|
Text
10511600000083_Undergraduate_Thesis.pdf Restricted to Repository staff only Download (4MB) | Request a copy |
Abstract
Transformator merupakan komponen yang sangat penting peranannya dalam sistem ketenagalistrikan terutama dalam mendistribusikan listrik dari pembangkit listrik ke rumah-rumah ataupun ke pelanggan yang lain (industri, kantor, dll.) Transformator selalu digunakan sepanjang hari tanpa henti karena jika sekali dihentikan, pendistribusian listrik pun akan terhenti dan akan menyebabkan kerugian bagi produsen serta konsumen. Untuk itu perlu adanya sebuah sistem monitoring beberapa variabel penting dalam distribusi listrik oleh transformator yaitu tegangan, arus dan frekuensi. Sistem ini nantinya dapat digunakan sebagai acuan untuk mendeteksi kerusakan transformator secara dini tanpa harus menghentikan proses distribusi. Dalam tugas akhir ini telah dibuat perancangan alat monitoring dengan menggunakan sensor tegangan, arus dan frekuensi dengan masing-masing sensor yang digunakan adalah ZMPT101b, ACS712 dan IC H11AA1. Nilai pembacaan ini diproses dengan mikrokontroler ARM STM32F407VG-Discovery. Nilai error yang didapatkan pada pembacaan sensor adalah 0,00-0,01% untuk sensor tegangan, 0,02-0,04% untuk sensor arus dan 0,00-0,01% untuk pembacaan nilai frekuensi. Nilai tersebut akan ditampilkan pada LCD dan disimpan dalam SD Card. Alat ini juga dilengkapi dengan modul Bluetooth agar dapat diakses dengan menggunakan ponsel Android.
====================================================================================================================================
Transformer is a component that has a very important role in the electricity system especially in distributing electricity from power plants to homes or to other customers (industries, offices, etc.). The transformer is always used all day without stopping because if it is stopped once, the distribution of electricity will be stopped and will cause losses to producers and consumers. For this reason, it is necessary to have a monitoring system of several important variables in the electricity distribution by the transformer, such as voltage, current and frequency. This system can later be used as a reference to detect transformer damage earlier without having to stop the distribution process. In this final project the design of a monitoring device has been made using voltage, current and frequency sensors with each sensor used is ZMPT101b, ACS712 and IC H11AA1. This readable value is then processed with the ARM STM32F407VG-Discovery microcontroller. The error value obtained in these sensor readings is 0.00-0.01% for voltage sensors, 0.02-0.04% for current sensors and 0.00-0.01% for reading frequency values. This value will be displayed on the LCD and stored in the SD Card. This device is also equipped with a Bluetooth module so that it can be accessed using an Android phone.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, Monitoring, Tegangan, Arus, Frekuensi, Mikrokontroler, LCD, SD Card |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK6565.T7 Transformers |
| Divisions: | Faculty of Vocational > Instrumentation Engineering |