Telah dilakukan pembuatan alat ukur ketinggian
permukaan air sungai mengguakan prinsip tekanan berbasis
Mikrokontroler Atmega328. Besaran ketinggian permukaan air
yang sebanding dengan tekanan di dalam Air akan dirubah
menjadi besaran tekanan dengan menggunakan pipa transmiter
yang di dalam terdapat sensor tekanan BMP085. Data diolah
dengan menggunakan mikrokontroler ATmega382, yang
kemudian ditampilkan pada liquid cristal display (LCD) 16x2.
Berdasarkan penelitian yang telah dilakukan, pipa transmitter
dapat digunakan mengukur ketinggian permukaan air dengan
menggunakan prinsip tekanan. Sensor Tekanan BMP085 dan
pipa transmitter yang dirancang mampu digunakan dengan baik
dengan berdasarkan pada faktor kalibrasi:
Level=11,52×Tekanan – 11612 mm. Ketika pengujian sistem,
ketinggian ketinggian permukaan air pasang di pintu air kali
Wonorejo, Surabaya dapat diamati dengan faktor koreksi : Level
= 11,47×Tekanan – 10149 mm.

============================================================================================
Measuring instrument of water level has been
manufactured using presure principle by ATMEGA328
microcontroler based. The quantity of the water level is
propotional to the presure in the water will be converted to
pressure quantities using a pressure sensor in the pipeline
transmitter. Data is processed using atmega microcontroller is
then displayed on the Liquid Crystal Display (LCD) 16x2. Based
on the research, the pipeline transmitter can be used to measure
the water level using the principle of pressure. BMP085 pressure
sensor and pipe transmitter that have been designed are capable
to be used based on calibration factors Level = 11.52 x pressure -
11612 mm. When testing the system, the tide water level at the
Wonorejo dam Surabaya was observed by a correction factor
level = 11.47 x pressure - 10149 mm.

Item Type: Thesis (Undergraduate)
Additional Information: RSFi 629.895 Fah r
Uncontrolled Keywords: Prinsip tekanan, Pengukuran level, Tinggi permukaan air
Subjects: Q Science > QC Physics > QC100.5 Measuring instruments (General)
Divisions: Faculty of Mathematics and Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: - Taufiq Rahmanu
Date Deposited: 30 Oct 2019 07:18
Last Modified: 30 Oct 2019 07:18
URI: http://repository.its.ac.id/id/eprint/71508

Actions (login required)

View Item View Item