Studi Perbandingan Pengaruh Penambahan SDVA Dan DDVA Tersusun Seri Terhadap Respon Getaran Translasi Sistem Utama

Lostari, Aini (2015) Studi Perbandingan Pengaruh Penambahan SDVA Dan DDVA Tersusun Seri Terhadap Respon Getaran Translasi Sistem Utama. Masters thesis, Institut Teknology Sepuluh Nopember.

[thumbnail of 2113205002-Master Thesis.pdf]
Preview
Text
2113205002-Master Thesis.pdf - Published Version

Download (3MB) | Preview

Abstract

Pada rotating equipment, getaran merupakan masalah yang tidak bisa
dihindari. Getaran yang berlebihan bisa menimbulkan kerusakan, sehingga perlu
direduksi. Salah satu cara mereduksi getaran yang berlebih, khususnya pada
sistem yang bergetar dengan frekuensi tunggal, adalah dengan penambahan DVA.
Secara umum DVA adalah penambahan massa-pegas-peredam pada sistem utama.
Dalam penelitian dilakukan studi perbandingan pengaruh SDVA (Single
dynamic vibration absorber ) dan DDVA (Dual Dynamic Vibration Absorber)
tersusun seri pada sistem utama terhadap penurunan respon getarannya. Pada
penelitian digunakan motor listrik sebagai sumber putaran dan diletakkan pada
beam yang bertujuan untuk menghasilkan getaran. Sumber getaran dihasilkan
dengan penambahan massa unbalance pada disk yang diputar oleh motor listrik
yang terletak di atas (beam) sistem utama. Dari bentuk fisik yang ada kemudian
dibangunlah persamaan dinamis dan blok simulasi. Untuk memverifikasi
kebenaran dari hasil simulasi, maka dilakukan eksperimen. Dari penelitian akan
diketahui perbandingan respon getaran pengaruh SDVA dan DDVA tersusun seri
pada sistem utama.
Pada penelitian didapatkan respon getaran yang mampu mereduksi pada
SDVA dengan massa absorber 1/10 didapatkan rms displacement sebesar
0.007287 m dan rasio frekuensi sebesar 0.8585. Sedangkan DDVA didapatkan
rms displacement sebesar 0.006379 m dan rasio frekuensi sebesar 0.9136.
Sehingga pada kasus SDVA dan DDVA dimana sistem DVA yang mampu
mereduksi getaran berlebih pada sistem dengan frekuensi tunggal yaitu SDVA
dimana massa absorber 1 dalam mereduksi getaran massa utama berkurang karena
adanya massa absorber 2 yang mengurangi kemampuan getaran pada massa
absorber 2.
=======================================================================================================
Vibrations are a common problem in the rotating machinery. Excessive
vibration responses could yield damage so that has to be reduced. The way to do
it, especially for single operating frequency, is adding the dynamic vibration
absorber. Generally, the dynamic vibration absorber is a mass-spring-damper
addition to the main system.
This study researches the effects comparison of Single Dynamic Vibration
Absorber and Series Double Dynamic Vibration Absorber on the main system
response. Electric motor with unbalanced masses is used as the exciter and placed
on the two beams. The main mass is supported by these beams. This system has
the specified dynamic equations. The simulation model is validated by comparing
its results with the experimental results. The main system responses of the SDVA
and series DDVA are known and compared each other.
The main system response with 1/10 absorber mass SDVA addition gives
0,007287 m displacement rms at 0,8585 frequency ratio. The one with DDVA
gives 0,006379 m displacement rms at 0,9136 frequency ratio. The system with
SDVA gives better response than DDVA. The first absorber mass ability to
reduce main mass response is disturbed by the second absorber mass existence.

Item Type: Thesis (Masters)
Additional Information: RTM 629.243 Los s
Uncontrolled Keywords: Single dynamic vibration absorber, Dual Dynamic Vibration Absorber, Getaran Translasi
Subjects: T Technology > TL Motor vehicles. Aeronautics. Astronautics > TL257.5 Automobiles--Shock absorbers--Design and construction.
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21101-(S2) Master Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 13 Nov 2019 02:56
Last Modified: 13 Nov 2019 02:56
URI: http://repository.its.ac.id/id/eprint/71738

Actions (login required)

View Item View Item