Rancang bangun sistem pengendalian level pada tangki pemanas mini plant heat exchanger berbasis mikrokontroller

Syam, Dio Arganata Aris (2016) Rancang bangun sistem pengendalian level pada tangki pemanas mini plant heat exchanger berbasis mikrokontroller. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2413031033-non degree thesis.pdf]
Preview
Text
2413031033-non degree thesis.pdf

Download (1MB) | Preview

Abstract

Sistem pertukaran panas sangatlah dibutuhkan untuk
kegiatan sehari-hari. Pada dunia industri, heat exchanger
digunakan untuk memanfaatkan suatu fluida yang dalam keadaan
panas agar panas tersebut berpindah ke fluida lain untuk
diproses lebih lanjut. Pengendalian level diperlukan untuk
menjaga ketinggian fluida pada tangki yang akan masuk ke
dalam heat exchanger. Sistem pengendalian ini menggunakan
sensor ultrasonik HC-SR04 dan mikrokontroller ATmega 8535
sebagai kontroller. Aktuator yang digunakan berupa pompa.
Nilai dari pembacaan sensor akan ditampilkan pada LCD. Set
point yang digunakan untuk mematikan pompa sebesar 20 cm.
Berdasarkan hasil dari pengujian yang telah dilakukan, diketahui
karakteristik statik dari sensor yang memiliki akurasi 0,99 cm
dan error 0,00004 cm dengan range 5 cm - 50 cm dan span
sebesar 45 cm, nilai ketidakpastian diperluas dari sensor sebesar
±1,01188 cm. Untuk respon sistem pengendalian level, diketahui
nilai settling time sebesar 40 detik pada set point 20 cm, 12 detik
dari set point 20 cm menuju 25 cm dan 11 detik dari set point 25
cm menuju 30 cm. Nilai maximum overshoot sistem sebesar 1
cm. Nilai error steady state dari masing-masing set point yaitu
0,090909 untuk 20 cm, 0,890411 untuk 25 cm dan 0,272727 untuk
30 cm.

==========================================================================================================

Heat exchanger system is desperately needed for day-to-day
activities. In the industrialized world, a heat exchanger used to
utilize a fluid in hot conditions in order to heat the fluid to
migrate to another for further processing. Controlling the level
needed to keep the height of the fluid in the tank to be entered into
the heat exchanger. The control system uses HC-SR04 ultrasonic
sensor and microcontroller ATmega 8535 as controller.
Actuators are used in the form of a pump. The value of the sensor
readings are displayed on the LCD. Set point used to turn off the
pump by 20 cm. Based on the results of the testing that has been
done, it is known static characteristics of the sensor which has an
accuracy error of 0.99 cm and 0.00004 cm with a range of 5 cm -
50 cm and a span of 45 cm, the value of the expanded uncertainty
of ± 1.01188 cm sensor , For the response level control system,
known value of settling time of 40 seconds at set point 20 cm, 12
seconds from a set point of 20 cm to the 25 cm and 11 seconds
from a set point of 25 cm to the 30 cm. System overshoot
maximum value of 1 cm. Error steady state value of each set point
is 0.090909 to 20 cm, 25 cm and 0.890411 to 0.272727 to 30 cm.

Item Type: Thesis (Diploma)
Additional Information: RSF 629.895 Sya r
Uncontrolled Keywords: sistem pengendalian level, karakteristik statik, respon sistem pengendalian
Subjects: Q Science > QC Physics
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3
Depositing User: - Taufiq Rahmanu
Date Deposited: 27 Nov 2019 02:36
Last Modified: 27 Nov 2019 02:36
URI: http://repository.its.ac.id/id/eprint/72073

Actions (login required)

View Item View Item