Abstract

Telah dibuat sistem penyaringan air dengan menggunakan sensor turbidity dengan memanfaatkan tingkat kekeruhan air dan juga sensor level yang memanfaatkan tingkat ketinggian air. Air yang kotor dibersihkan melalui filter dan air yang sudah bersih ditampung di tangki terpisah. Hasil pengukuran dapat dilihat di display. Dari pengambilan data dengan 4 jenis air yang berbeda yaitu air minum kemasan, air minum isi ulang, air keran dan air sumur maka didapatkan rata-rata hasil pembacaan tingkat kekeruhan (NTU) untuk masing-masing jenis air dengan interval pengambilan data 5 detik adalah 4,03 untuk air minum kemasan, 5,46 untuk air minun isi ulang, 6,29 untuk air keran, dan 7,87 untuk air sumur. Sehingga dapat disimpulkan bahwa nilai kekeruhan (NTU) untuk masing-masing jenis air ditentukan dari bagaimana air tersebut diperoleh dan darimana sumbernya. ====================================================================================================================================
Water filtration systems have been assembled using turbidity sensors by utilizing the level of turbidity of water and also level sensors that utilize water level. Dirty water is cleaned through filters and clean water is collected in separate tank. The measurement results can be seen on the display. From the collected data with 4 different types of water, namely bottled water, refill drinking water, tap water and well water, the average turbidity level reading (NTU) for each type of water obtained with a 5-second data collection interval is 4,03 for bottled water, 5,46 for refill water, 6,29 for tap water, and 7,87 for well water. So it can be concluded that the turbidity value (NTU) for each type of water is determined by how the water is obtained and where the source is.

Item Type: Thesis (Diploma)
Additional Information: RSMI 629.895 Pra r-1
Uncontrolled Keywords: turbidity, level, filter
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Vocational > Instrumentation Engineering