Tassia, Ranti Dwi (2016) Evaluasi Nilai Airborne Sound Insulation Dan Prediksi Flanking Path Pada Ruang Kelas UPT Bahasa Its. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
2412100092-Undergraduate_Thesis.pdf - Accepted Version Download (1MB) | Preview |
Abstract
UPT Bahasa merupakan salah satu unit milik ITS yang menfasilitasi mahasiwa maupun umum dalam rangka mengikuti course program, test program dan kegiatan budaya lainnya. Performansi dari ruang kelas yang ada pada gedung UPT khususnya dari segi kenyamanan akustik merupakan aspek yang penting untuk diperhitungkan. Salah satu parameter untuk meninjau kenyamanan akustik adalah berdasarkan nilai insulasi partisi pada ruang kelas. Nilai insulasi dapat dinyatakan dengan nilai rugi transmisi bunyi yang diubah menjadi sebuah nilai tunggal yaitu weighted sound reduction index (Rw, DnTw) dan mempunyai penambahan faktor koreksi suara frekuensi rendah (C, Ctr).Pada penelitian ini pengukuran dilakukan pada dua posisi titik pengambilan data dengan menggunakan microphone BSWA dan speaker dodecahedron sebagai sumber suara. Hasil pengukuran di lapangan menunjukkan nilai insulasi akustik yang diperoleh (DnTw+C) adalah sebesar 19,6 dB. Hasil yang diperoleh sangat jauh jika dibandingkan dengan standar yang ada yaitu DnTw+C > 51 dB. Oleh sebab itu perlu adanya perancangan ulang untuk meningkatkan insulasi akustik pada partisi ruang kelas. Pada perancangan dipilih beberapa material yaitu gypsum board, plasterboard, cement board, dan PVC. Berdasarkan hasil yang diperoleh, semua material yang disimulasikan sesuai dengan standar yang ditetapkan. Nilai insulasi terbaik sebesar 69 dB dimiliki material cement board dengan ketebalan 12.5 mm pada masing-masing sisi dan material absorber sebesar 50 mm.
========================================================================================================
"UPT Bahasa is one of the units belonging to ITS that facilitating the students and the public in order to attend the course program, test program and other cultural activities. The performance of the existing classrooms at UPT bahasa in terms of acoustic comfort is an important aspect to be taken into account. One of the parameters to review the acoustic comfort is based on the value of the insulation partition in the classroom. The insulation value can be expressed by the sound transmission loss which converted into a single value as weighted sound reduction index (Rw, DnTw) and also have an additional sound correction factor in low frequency (C, Ctr) . In this study, the measurements were performed in two positions at each point using BSWA microphone and dodecahedron speaker as the sound source. The results of field measurements indicate the acoustic insulation values (DnT w + C) is 19.6 dB. It is noted that the partition wall not according to the standard DnTw + C> 51 dB. Hence the partition wall need to be redesign to improve acoustic insulation in the classroom. The design used gypsum boardm plasterboard, cement board, and PVC as the replacement material. Based on the results, all the material is simulated in accordance with established standards. Best insulation is cement board with the insulation value is 69dB and the thickness of 12.5 mm on each side and the absorber material
is 50 mm.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSF 620.23 Tas e |
Uncontrolled Keywords: | Insulasi; dinding partisi; perancangan; flanking path |
Subjects: | T Technology > TD Environmental technology. Sanitary engineering > TD892 Noise control |
Divisions: | Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis |
Depositing User: | Yeni Anita Gonti |
Date Deposited: | 03 Jun 2020 04:07 |
Last Modified: | 03 Jun 2020 04:07 |
URI: | http://repository.its.ac.id/id/eprint/76067 |
Actions (login required)
View Item |