Rancang Bangun Sistem Monitoring Temperatur Pada Mini Plant Heat Exchanger Tipe Shell Dan Tube Berbasis Microsoft Visual Basic

Sari, Devi Nur Indah (2016) Rancang Bangun Sistem Monitoring Temperatur Pada Mini Plant Heat Exchanger Tipe Shell Dan Tube Berbasis Microsoft Visual Basic. Diploma thesis, Institut Teknologi Sepuluh Nopember Surabaya.

[thumbnail of 2413031024-Non_Degree.pdf]
Preview
Text
2413031024-Non_Degree.pdf - Published Version

Download (4MB) | Preview

Abstract

Heat Exchanger adalah sebuah unit yang berfungsi untuk
memanaskan suatu fluida produk dengan mengambil energi panas dari
media lain, dimana terjadi perpindahan panas dari fluida yang
temperaturnya lebih tinggi ke fluida yang temperaturnya lebih rendah.
Heat exchanger tipe shell dan tube merupakan tipe heat exchanger yang
melibatkan tube sebagai komponen utamanya, di mana salah satu fluida
mengalir di dalam tube, sedangkan fluida lainnya mengalir di luar tube
(shell). Temperatur merupakan salah satu besaran fisis yang perlu di
kontrol dan monitoring. Pada penelitian ini telah dilakukan sistem
monitoring temperatur pada sisi output bagian shell dan tube heat
exchanger. Sistem ini terdiri dari sensor termokopel tipe K, rangkaian
pengkondisian dan penguat sinyal dengan IC AD595 dan LM358,
mikrokontroler ATMega 16, kabel serial RS232 dan RJ11, display LCD
16x2 serta display pada komputer melalui software Microsoft Visual
Basic 2013. Monitoring dilakukan dengan waktu pengukuran setiap 1
dan 2 menit. Berdasarkan hasil pengujian temperatur diperoleh dari
nilai ketidakpastian pengukuran sebesar ±0,124418oC dengan tingkat
kepercayaan 95%. Dari hasil pengujian alat pada plant heat exchanger
bagian tube, diperoleh nilai penurunan temperatur sebesar 37,14 oC
dari temperatur terukur 74,29oC menjadi 37,15 oC dengan waktu
tempuh 32 menit untuk time sampling setiap 1 menit. Dan pada time
sampling 2 menit diketahui perubahan temperatur sebesar 21,99 oC
dengan waktu tempuh 26 menit dari temperatur yang mulanya 57,18 oC
menjadi 35,19 oC. Pada set point tube inlet 75 oC, tube outlet 45 oC,
shell inlet 29,81 oC dan shell outlet 42,52 oC diperoleh nilai efisiensi
perpindahan panas sebesar 0,56
==============================================================================================
Heat Exchanger is a function unit for heating a product of fluid
with taking heat energy from other medium, where there is a heat
transfer from a higher temperature fluid to a lower temperature fluid.
Heat exchanger shell and tube type is a type of heat exchanger that
involves tube as its main component, in which one of the fluids flowing
in the tube, while the other fluid flowing outside the tube (shell).
Temperature is one of the physical quantities that need to be in control
and monitoring. This study has been carried out the temperature
monitoring system on the output side section shell and tube heat
exchanger. The system consists of a sensor K type thermocouple,
conditioning and amplifier signal circuit with AD595 and LM358 IC,
microcontroller ATMega 16, RS232 serial cable and RJ11, 16x2 LCD
display and display on a computer through software Microsoft Visual
Basic 2013. Monitoring is doing by measuring the time every 1 and 2
minutes. Based on test results obtained showed that the temperature
measurement uncertainty of ± 0,124418oC value with 95% confidence
level. From the results of testing tools in plant heat exchanger tube
section, the value of 37,14 °C decrease in temperature of measured
temperature 74,29 oC be 37.15 oC with a travel time of 32 minutes to
each of time sampling 1 minutes. And on 2 minutes time sampling
ascertainable temperature changes the value of 21,99 oC with a travel
time 13 minutes from the temperature begin 57,18 oC to 35,19 oC. At set
point value of tube inlet 75 oC, 45 oC tube outlet, 29,81 oC shell inlet and
42,52 oC shell outlet gets heat transfer efisiensi of value 0,56

Item Type: Thesis (Diploma)
Additional Information: RSF 621.402 5 Sar r
Uncontrolled Keywords: Temperatur, monitoring, heat exchanger, shell, tube, visual basic
Subjects: H Social Sciences > HD Industries. Land use. Labor > HD9696 Temperature control equipment
T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3
Depositing User: EKO BUDI RAHARJO
Date Deposited: 30 Jul 2020 01:17
Last Modified: 30 Jul 2020 01:17
URI: http://repository.its.ac.id/id/eprint/76713