Analisis Penghematan Energi Sistem Distribusi Air Minum Jalur Kaum Pandak Perumda Air Minum Tirta Kahuripan Kabupaten Bogor

Maharani, Astri (2021) Analisis Penghematan Energi Sistem Distribusi Air Minum Jalur Kaum Pandak Perumda Air Minum Tirta Kahuripan Kabupaten Bogor. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 6014201036-Master_Thesis.pdf] Text
6014201036-Master_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2024.

Download (4MB) | Request a copy

Abstract

Biaya energi merupakan salah satu komponen biaya operasional dalam sistem distribusi air minum. Berdasarkan data dari Perumda Air Minum Tirta Kahuripan, salah satu penyumbang pemakaian energi yang besar di Kabupaten Bogor adalah sistem instalasi dan distribusi di Cabang Cibinong, dengan pemakaian energi spesifik (SEC) lebih besar daripada 0,4 kWh/m3 di Jalur Kaum Pandak pada tahun 2018. Oleh karena itu, penelitian ini bertujuan untuk menganalisis upaya penghematan energi yang sesuai dengan kondisi eksisting sistem distribusi Jalur Kaum Pandak.
Penelitian ini menganalisis pemakaian energi dan efisiensi kinerja eksisting pompa distribusi serta menganalisis kinerja jaringan distribusi dengan melakukan pemodelan dengan EPANET 2.2, survei tekanan, dan survei 98 sampel pelanggan dari total populasi 4.308. Selanjutnya diberikan rekomendasi upaya penghematan energi yang dapat dilakukan yang dikaji dari aspek teknis dan finansial.
Hasil penelitian menunjukkan nilai SEC untuk pompa 1 dan pompa 2 adalah 0,40 kWh/m3 dan efisiensi kinerja untuk pompa 1 dan pompa 2 adalah 44,38% dan 43,02%. Hasil simulasi jaringan perpipaan dengan EPANET didapatkan nilai tekanan, kecepatan aliran, dan headloss tidak melebihi standar maksimum yang berlaku. Namun untuk kecepatan aliran dalam pipa beberapa nilai tidak memenuhi standar minimum karena dimensi pipa dirancang untuk dapat mengakomodasi penambahan kebutuhan air. Rekomendasi upaya yang dapat dilakukan adalah dengan melakukan penggantian pompa dan pengaturan VSD yang dapat menghemat energi sebesar 9.653,87 kWh per bulan atau senilai Rp 10.827.879,33 per bulan, Nilai NPV yang didapat dari upaya ini adalah sebesar Rp 1.587.717.221,00 dan nilai BCR sebesar 1,11.
================================================================================================
Energy cost is one of the components of operational expenditure in the water distribution system. Based on the data from Perumda Air Minum Tirta Kahuripan, one of the installation systems that contributes a large amount of energy consumption was located in Cibinong, with Kaum Pandak distribution system having largest SEC value in 2018. Therefore, this study aimed to analyze the form of energy saving in accordance with the existing condition.
This study analyzed the energy consumption and efficiency of the existing distribution pumps, and the distribution network. The distribution network was analyzed by doing network modeling with EPANET 2.2, pressure monitoring, and distributing questionnaires to 98 samples of customers. Furthermore, technical recommendations were given according to the design criteria and were analyzed financially as well.
The results showed that SEC for pump 1 and pump 2 was 0.40 kWh/m3 and the efficiency for pump 1 and pump 2 was 44.38% and 43.02%, respectively. Network analysis showed that the pressure and headloss values had met the standard. Meanwhile for velocity, there were still many pipes with values below the minimum standard due to accommodating future water demand. The chosen recommendation for energy saving was to replace both pumps and use VSD, which can save 9,653.87 kWh of electricity per month, and energy cost of Rp 10,827,879.33 per month. The NPV obtained was Rp 1,587,717,221.00 and the BCR value was 1.11.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Energy, Pumps, Tirta Kahuripan, VSD, Water Distribution System, Energi, Pompa, Sistem Distribusi Air Minum, Tirta Kahuripan, VSD
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD481 Water distribution systems
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Environmental Engineering > 25101-(S2) Master Thesis