Pengurangan Energi Insiden Busur Api Dengan Menggunakan Metode Zone Selective Interlocking Pada PT. Petrokimia

Fauzan, Muhammad Irfan (2022) Pengurangan Energi Insiden Busur Api Dengan Menggunakan Metode Zone Selective Interlocking Pada PT. Petrokimia. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 07111940000183-Undergraduate_Thesis.pdf] Text
07111940000183-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2025.

Download (2MB) | Request a copy

Abstract

PT Petrokimia Gresik merupakan pabrik pupuk yang berdiri pada 10 Juli 1972. PT Petrokimia Gresik saat ini menempati areal lebih dari 450 hektar di Kabupaten Gresik, Jawa Timur dengan Total produksi saat ini mencapai 8,9 juta ton/tahun, terdiri dari produk pupuk sebesar lima juta ton/tahun, dan produk non pupuk sebanyak 3,9 juta ton/tahun. Oleh karena itu untuk menunjang jumlah produksi tersebut diperlukan koordinasi yang baik dari setiap sektor produksi, serta sistem keamanan yang dapat menjamin keselamatan pekerjanya maupun aset perusahaan. Salah satu bahaya yang dapat mengancam keselamatan pekerja maupun keberlangsungan produksi adalah arc flash. Menurut National Fire Protection Association (NFPA) 70E arc flash adalah kondisi berbahaya yang terkait dengan pelepasan energi yang disebabkan oleh busur listrik. Efek yang dihasilkan arc flash dapat berupa ledakan, radiasi panas, cahaya yang menyilaukan, dan tekanan yang sangat besar. Energi yang dilepaskan dapat memanaskan udara sekitar hingga suhu ekstrem seperti hampir 20.000 °C. Pada temperatur tersebut, sesuatu yang berada dalam jarak 1 meter dapat terbakar ataupun meleleh. Terdapat beberapa cara untuk mencegah terjadinya arc flash ataupun mengurangi bahaya yang dapat ditimbulkan. Salah satu metode yang dapat dipilih untuk mengatasi bahaya arc flash tersebut adalah Zone Selective Interlocking (ZSI). Zone Selective Interlocking dipilih dikarenakan ZSI dapat membatasi tekanan pada sistem dengan mengurangi waktu yang diperlukan untuk mengatasi gangguan dengan tetap mempertahankan koordinasi sistem. Setelah itu dilakukan evaluasi untuk mengetahui energi insiden arc flash setelah diterapkannya metode ZSI serta menentukan peralatan keselamatan bagi pekerja atau Personal Protective Equipment (PPE). Hasil yang didapat dari penerapan metode ZSI ini adalah pengurangan level kategori bahaya dari level 3 dan 4 menjadi level 2. ==============================================================================================================================
PT Petrokimia Gresik is a fertilizer factory that was established on July 10, 1972. PT Petrokimia Gresik currently occupies an area of more than 450 hectares in Gresik Regency, East Java with a current total production of 8.9 million tons/year, consisting of fertilizer products with a total five million tons/year, and non-fertilizer products as much as 3.9 million tons/year. Therefore, to support that amount of production, good coordination is needed from each production sector, as well as a protection system that can ensure the safety of its workers and company assets. One of the hazards that can threaten the safety of workers and the continuity of production is arc flash. According to the National Fire Protection Association (NFPA) 70E arc flash is a hazardous condition associated with the release of energy caused by an electric arc. The effects produced by arc flash can be in the form of explosions, heat radiation, dazzling light, and enormous pressure. The energy released can heat the ambient air to extreme temperatures such as nearly 20,000 °C. At that temperature, something within 1 meter of it can burn or melt. There are several ways to prevent arc flash or reduce the danger it can cause. One method that can be chosen to overcome the danger of arc flash is Zone Selective Interlocking (ZSI). Zone Selective Interlocking was chosen because ZSI can limit the stress on the system by reducing the time required to resolve disturbances while maintaining system coordination. After that, an evaluation was carried out to determine the energy of the arc flash incident after the application of the ZSI method and determine safety equipment for workers or known as Personal Protective Equipment (PPE). The result obtained from the application of the ZSI method is a reduction in the level of hazard category from level 3 and 4 to level 2.

Item Type: Thesis (Other)
Uncontrolled Keywords: PT. Petrokimia, incident energy, Personal Protective Equipment, energi insiden, arc flash, Zone Selective Interlocking,
Subjects: T Technology > T Technology (General) > T56.8 Project Management
T Technology > T Technology (General) > T57.62 Simulation
T Technology > TK Electrical engineering. Electronics Nuclear engineering
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2861 Electric relays
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3030 Electric power distribution systems
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Muhammad Irfan Fauzan
Date Deposited: 01 Feb 2023 04:04
Last Modified: 01 Feb 2023 04:04
URI: http://repository.its.ac.id/id/eprint/95732

Actions (login required)

View Item View Item