Sistem Informasi Untuk Rehabilitasi Jarak Jauh Dengan Siaran Video Langsung Menggunakan Kamera Pan Tilt Zoom

Darmawan, Seno Aji (2023) Sistem Informasi Untuk Rehabilitasi Jarak Jauh Dengan Siaran Video Langsung Menggunakan Kamera Pan Tilt Zoom. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 07311840000049-Undergraduate_Thesis.pdf] Text
07311840000049-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2025.

Download (6MB) | Request a copy

Abstract

Telemonitoring merupakan layanan yang memberikan akses kemudahan bagi praktisi kesehatan untuk melakukan pengamatan dari kesehatan pasiennya. Telemonitoring memberi keuntungan bagi pasien yang memiliki kesulitan untuk melakukan transportasi ke tempat rehabilitasi tetapi membutuhkan pemeriksaan rutin seperti golongan tua, pasien rehabilitasi stroke, dan lainnya. Dalam penelitian ini diusulkan suatu applikasi untuk pemantauan rehabilitasi dengan metode streaming video secara daring. Alat perekaman yang diajukan berupa kamera pan tilt zoom (PTZ). Hal ini menguntungkan pasien dimana karena masalah pergerakan pasien tidak perlu mendekat atau menjauh karena kamera dapat diatur oleh praktisi sendiri. Untuk perangkat keras yang digunakan merupakan kamera PTZ dari Hikvision komputer yang sudah melakukan instalasi webcomponentkit.exe. Hasil dari penelitian ini berupa terbentuknya sistem informasi untuk rehabilitasi jarak jauh dengan menggunakan kamera PTZ. Hasil dari pengujian lingkungan tempat implementasi didapatkan bahwa browser yang harus digunakan berupa google chrome dengan plugin IE tab serta perlu VLC Media Player untuk memutar video rekaman. Pengujian black box testing menunjukan sistem informasi berjalan sesuai ekspetasi rancangan. Hasil dari pengujian parameter QoS menunjukan waktu memakai sistem informasi tidak mempengaruhi nilai parameter. Dari pengujian kualitas video live view nilai delay semakin rendah dan nilai throughput semakin tinggi dengan semakin meningkatnya kualitas video. Lalu untuk pengujian terhadap daerah tempat mengakses tidak mempengaruhi parameter dengan data bahwa walaupun delay menggunakan WiFi kampus lebih rendah tetapi memiliki packet loss lebih banyak dibandingkan menggunakan internet telepon genggam di daerah luar kampus. Untuk pengujian memori diuji terhadap kualitas video dan gerakan. Untuk menghemat tempat penyimpanan disarankan menggunkan kualitas lowest sudah cukup untuk perbulan dengan adanya banyak pergerakan bisa menghabiskan dari 3312 mb hingga 5520 mb. Dilakukan simulasi terhadap penggunaan exoskeleton upper limb dan FES upper limb terhadap parameter QoS dan memori. Hasil pengujian terakhir yaitu user experience testing memiliki nilai positif dari subjek dengan profesi di bidang terkait serta dari subjek umum. Untuk pengembangan selanjutnya bisa dilakukan integrasi sistem informasi dengan fitur telerehabilitasi lainnya seperti data alat rehabilitasi FES, ditambahkannya enkripsi keamanan untuk data pasien dan akses kamera, serta kompresi data video yang telah direkam.
======================================================================================================================================
Telemonitoring is a service that provides easy access for health practitioners to observe the health of their patients. Telemonitoring provides benefits for patients who have difficulty transporting themself to a rehabilitation center but need routine checks such as the elderly, stroke rehabilitation patients, and others. This research proposes an application for rehabilitation monitoring using the online video streaming method. The proposed recording device is a pan tilt zoom (PTZ) camera. This is advantageous for patients where due to movement problems the patient does not need to get closer or further away because the camera can be adjusted by the practitioner himself. The hardware used is a PTZ camera from Hikvision, and a computer that has installed webcomponentkit.exe. The result of this research is a information system for remote rehabilitation using a PTZ camera. The results of testing the environment where it was implemented found that the browser that had to be used was Google Chrome with the IE tab plugin and needed VLC Media Player to play recorded videos. Black box testing shows that the information system is running according to design expectations. The results of testing the QoS parameters show that the time to use the information system does not affect the parameter values. From testing the live view video quality, the delay value is lower and the throughput value is higher as the video quality increases. Then for testing the area where access does not affect parameters with the data that even though the delay using campus WiFi is lower, it has more packet loss than using mobile internet outside the campus area. For memory testing tested against video quality and movement. To save storage space, it is recommended to use the lowest quality, which is enough for a month with lots of movements, it can spend from 3312 mb to 5520 mb. Simulations were carried out on the use of the upper limb exoskeleton and upper limb FES on QoS and memory parameters. The results of the last test, user experience testing, have positive values from subjects with professions in related fields as well as from general subjects. For further development, information system integration can be carried out with other telerehabilitation features such as FES rehabilitation equipment data, added security encryption for patient data and camera access, as well as compressed video data that has been recorded.

Item Type: Thesis (Other)
Additional Information: RSB 621.389 28 Dar s-1 2023
Uncontrolled Keywords: PTZ, Rehabilitasi, Streaming, Telemonitoring PTZ, Rehabilitation, Streaming, Telemonitoring
Subjects: R Medicine > RM Therapeutics. Pharmacology > RM950 Rehabilitation technology.
T Technology > T Technology (General) > T58.6 Management information systems
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK5105.888 Web sites--Design. Web site development.
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Biomedical Engineering > 11410-(S1) Undergraduate Thesis
Depositing User: Seno Aji Darmawan
Date Deposited: 14 Feb 2023 02:47
Last Modified: 11 Sep 2023 03:55