Widyatama, Bima Ersa (2023) Analisis Kerusakan Long Retractable Sootblower Boiler 8 Dengan Metode FMEA Di PLTU Paiton. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
10211810010027-Non_Degree.pdf - Accepted Version Restricted to Repository staff only until 1 April 2025. Download (2MB) | Request a copy |
Abstract
Energi listrik menjadi salah satu energi yang sangat diperlukan masyarakat di kehidupan sehari-hari. PT. POMI (Paiton Operations & Maintenance Indonesia) menjadi salah satu perusahaan swasta di Indonesia yang bergerak dibidang PLTU (Pembangkit Listrik Tenaga Uap) serta dimiliki oleh PT. PEC (Paiton Energi Company). Namun, karena uap untuk memutar turbin di PLTU Paiton berasal dari boiler dan bahan bakar untuk boiler di PT.POMI adalah batu bara, maka yang terjadi ialah sering kali terjadi peristiwa yang merugikan. Salah satunya yaitu fouling dan slagging. Fouling dan slagging merupakan peristiwa dimana abu batubara dan jelaga menempel dan menumpuk pada valve boiler dan heat recovery area. Untuk itu, maka PT. POMI menggunakan perlatan tambahan untuk boiler yaitu sootblower yang berfungsi untuk membersihkan debu, abu, atau jelaga yang menempel dan menumpuk pada pipa boiler dan heat recovery area dengan menggunakan media pembersih udara atau uap. Namun, pada tahun 2021 sootblower mengalami banyak kerusakan terutama long retractable sootblower. Untuk mengurangi kerusakan agar boiler kembali bekerja secara efisien, maka dilakukan analisis kerusakan dengan menggunakan metode FMEA untuk mendeteksi kerusakan komponen berdasarkan nilai severity, occurity, dan detection yang telah melalui proses diskusi dengan pihak maintenance dari PT. POMI dan menghasilkan RPN dengan cara mengalikan ketiga komponen tersebut. Setelah menemukan RPN maka diperoleh kasus kerusakan dengan RPN tertinggi yang akan dilakukan identifikasi perawatan yang tepat bagi komponen yang memiliki RPN tertinggi tersebut dengan harapan menurunnya frekuensi kerusakan daripada tahun-tahun sebelumnya dimana untuk kerusakan di bagian poppet valve yang memiliki RPN tertinggi yaitu katup mengalami stuck dan dilakukan pergantian spring untuk tindak pemeliharaannya. Lalu untuk kerusakan di bagian lance tube yang memiliki RPN tertinggi yaitu lance tube mengalami bending dan dilakukan pengembalian bentuk dengan cara bending pula.
======================================================================================================================================
Electrical energy is one of the energy that people really need in everyday life. PT. POMI (Paiton Operations & Maintenance Indonesia) is one of the private companies in Indonesia engaged in the PLTU (Steam Power Plant) and is owned by PT. PEC (Paiton Energy Company). However, because the steam to turn the turbines at the Paiton PLTU comes from boilers and the fuel for the boilers at PT.POMI is coal, what happens is that adverse events often occur. One of them is fouling and slagging. Fouling and slagging are events where coal ash and soot stick and accumulate in boiler valves and heat recovery areas. For that, PT. POMI uses additional equipment for boilers, namely sootblowers which function to clean dust, ash or soot that sticks to and accumulates on boiler pipes and heat recovery areas using air or steam cleaning media. However, in 2021 the sootblower suffered a lot of damage, especially the long retractable sootblower. To reduce damage so that the boiler can work efficiently again, a damage analysis is carried out using the FMEA method to detect component damage based on severity, occurrence, and detection values which have gone through a discussion process with the maintenance party from PT. POMI and produce RPN by multiplying the three components. After finding the RPN, the damage cases with the highest RPN will be identified which will identify the proper maintenance for the component with the highest RPN in the hope that the frequency of damage will decrease compared to previous years where for damage to the poppet valve which has the highest RPN, namely the valve is stuck and Spring replacement is done for maintenance. Then for damage to the lance tube that has the highest RPN, namely the lance tube is bent and the shape is restored by bending as well.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | long retractable sootblower, maintenance, failure mode and effect analysis, long retractable sootblower, maintenance, failure mode and effect analysis |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ174 Maintenance and repair of machinery |
Divisions: | Faculty of Vocational > Mechanical Industrial Engineering (D4) |
Depositing User: | Bima Ersa Widyatama |
Date Deposited: | 14 Feb 2023 03:53 |
Last Modified: | 14 Feb 2023 03:53 |
URI: | http://repository.its.ac.id/id/eprint/97181 |