Iklim tropis, dengan suhu yang mampu melebihi 31°C serta kelembapan relatif yang melampaui 70% mampu menjadi pemicu stress lingkungan. Secara konsisten, penelitian terdahulu menyimpulkan bahwa iklim tropis berdampak negatif terhadap aktivitas aerobik, dan secara umum berdampak pula pada individu dalam masa penyesuaian dengan kondisi yang sangat panas dan lembab. Sehingga, lingkungan termal yang meliputi suhu dan kelembapan merupakan salah satu faktor lingkungan terpenting yang berpengaruh terhadap kinerja manusia. Bersamaan dengan planet bumi yang menghangat, memastikan bahwa kebutuhan pendinginan terpenuhi secara cukup adalah hal yang sangat penting. Dari penelitian didapatkan bahwa pengaturan suhu dan kecepatan udara terbaik untuk AC DN (inverter) adalah pada suhu 25°C dengan kecepatan udara menggunakan blower level 2, sedangkan untuk AC SG (non-inverter), pengaturan terbaiknya adalah pada suhu 22°C dengan kecepatan udara menggunakan blower level 2. Pengaturan ini dipilih dengan mempertimbangkan faktor OEE, LCCA, dan Kenyamanan Termal. Dari kedua AC, mampu didapatkan nilai keandalan terbaik secara rata-rata pada AC DN jika ditinjau dari daya, AC SG memiliki keandalan yang lebih baik jika ditinjau dari temperatur. Untuk nilai LCCA, AC DN yang lebih rendah dibandingkan AC SG. Setelah dilakukan service, LCCA akan meningkat karena konsumsi energi yang juga meningkat, sehingga perlu disesuaikan pengaturan AC agar konsumsi energi tetap terkontrol. AC SG memiliki rata-rata OEE yang lebih tinggi yaitu 64,77%, dibandingkan dengan AC DN yang memiliki rata-rata OEE sebesar 61,55%. Secara keseluruhan, AC SG memiliki rentang OEE yang lebih stabil dibandingkan AC DN.
====================================================================================================================================
Tropical climate, with temperatures that can exceed 31°C and relative humidity that exceeds 70%, can trigger environmental stress. Consistent previous research has concluded that the tropical climate has a negative impact on aerobic activities and generally affects individuals who are adjusting to extremely hot and humid conditions. Therefore, thermal environment, which includes temperature and humidity, is one of the most important environmental factors that affect human performance. With the Earth warming up, ensuring sufficient cooling needs is crucial. From the research, it was found that the optimal temperature and airspeed settings for the DN (inverter) AC are at 25°C with the airspeed using blower level 2, while for the SG (non-inverter) AC, the optimal setting is at 22°C with the airspeed using blower level 2. These settings are chosen considering the factors of OEE, LCCA, and Thermal Comfort. From both AC units, the average reliability value is better for the DN AC when viewed from the power aspect, while the SG AC has better reliability when viewed from the temperature aspect. In terms of LCCA, the DN AC has a lower value compared to the SG AC. After service, the LCCA will increase due to increased energy consumption, so the AC settings need to be adjusted to control energy consumption. The SG AC has a higher average OEE of 64.77%, compared to the DN AC with an average OEE of 61.55%. Overall, the SG AC has a more stable OEE range compared to the DN AC.

Item Type: Thesis (Other)
Uncontrolled Keywords: Reliability, OEE, LCCA, Split Air Conditioner, Inverter
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General) > TA169 Reliability (Engineering)
T Technology > TS Manufactures > TS174 Maintainability (Engineering) . Reliability (Engineering)
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Tajuddin Ahmad Rafi
Date Deposited: 24 Jul 2023 14:35
Last Modified: 24 Jul 2023 14:35
URI: http://repository.its.ac.id/id/eprint/99158

Actions (login required)

View Item View Item