Analisis kebisingan dan rekomendasi rancangan partisi dalam pencapaian standar noise criteria bangunan pemukiman di rumah susun Urip Sumoharjo Surabaya

Sholah, Ayu (2015) Analisis kebisingan dan rekomendasi rancangan partisi dalam pencapaian standar noise criteria bangunan pemukiman di rumah susun Urip Sumoharjo Surabaya. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
1111100043-Undergraduate-Thesis.pdf

Download (693kB) | Preview

Abstract

Penelitian tentang kebisingan dan rekomendasi rancangan partisi dalam pencapaian standar noise criteria bangunan pemukiman di rumah susun urip sumoharjo Surabaya dilakukan untuk mengetahui distribusi kebisingan, nilai noise criteria ruang, serta pengaruh penambahan bahan uji pada nilai noise reduction dan noise criteria. Penelitian dilakukan dengan pengukuran distribusi kebisingan, noise criteria dan noise reduction ruang sebelum dan setelah penambahan bahan uji, serta perhitungan transmission loss dalam perancangan dinding muka. Bahan yang digunakan adalah gorden dengan bahan cotton 100 % tebal 0,1 cm. Dari hasil pengukuran dan analisis didapatkan bahwa kondisi bising paling tinggi yaitu 89 ± 3,41 dBA diperoleh di lantai 4 pada malam hari. Nilai noise criteria yang didapat tidak memenuhi standar yaitu, NC 61-69 untuk daerah ruang tamu, NC 61-67 untuk daerah tempat tidur, serta NC 61-64 untuk daerah dapur dan kamar mandi. Pengaruh bahan uji (gorden) terhadap noise reduction sebesar 4-13 dBA dan pada noise criteria sebesar 1-3 dBA atau setara dengan kenaikan kualitas sebesar 2 NC. ================================================================================================ Research on noise and partition design recommendation in achieving noise criteria standard of residential building in Urip Sumoharjo Surabaya flats was conducted to determine noise distribution, noise criteria, and the effect of materials adding on the value of noise reduction and noise criteria. The research was conducted by measuring the noise distribution, noise criteria, and noise reduction before and after the addition of material, and also the transmission loss calculation of the wall. The material used in the research was curtain with 100% cotton and 0,1 cm thick. From the measurement and analysis result, it was found that the highest condition was on the 4th floor flats at night with the value of 89 ± 3,41 dBA. The value of noise criteria are as followed, NC 61-69 in living room area, NC 61-67 in bed area, and NC 61-64 in kitchen area, which are not in accordance with the standard. However, the effect of material (curtain) on noise reduction are ranging between 4-13 dBA, and on the noise criteria are between 1-3 dBA, which are equivalent to a quality improvement as much as 2 NC.

Item Type: Thesis (Undergraduate)
Additional Information: RSFi 620.23 Sho a
Uncontrolled Keywords: kebisingan, noise criteria, noise reduction, sound pressure level (SPL), transmission loss
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD892 Noise control
Divisions: Faculty of Mathematics and Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Mr. Marsudiyana -
Date Deposited: 28 Nov 2019 06:26
Last Modified: 28 Nov 2019 06:26
URI: https://repository.its.ac.id/id/eprint/72101

Actions (login required)