Dewasa ini, kesadaran masyarakat akan pemanasan global semakin bertumbuh. Kesadaran akan pemanasan global ini meningkat sebagai akibat dari maraknya media penyebaran informasi, naiknya temperature permukaan bumi yang sudah semakin terasa dan perubahan cuaca dan musim yang semakin tidak beraturan. Salah satu alat yang berkontribusi dalam pemanasan global adalah alat pendingin yang digunakan oleh manusia. Semakin naiknya temperature permukaan bumi, penggunaan alat pendingin akan semakin meningkat dan semakin banyaknya penggunaan alat pendingin maka akan memperparah pemanasan global yang telah terjadi. Berdasarkan hal inilah penelitian ini dilakukan sebagai upaya untuk mencari solusi untuk hal ini. Data pada eksperimen yang dilakukan ini didapatkan dari mesin sistem refrijerasi Cascade, sistem refrijerasi dua tahap dimana pada High stage akan digunakan refrijeran Musicool-22 (propane) dan menggunakan R-407F pada Low stage. Refrijeran R-407F adalah refrijeran yang diajukan pada eksperimen ini untuk menggantikan R-404a yang dipakai pada pengujian menggunakan sistem cascade karena tingkat pencemarannya yang rendah dan properti dari fluida tersebut. Karakteristik kerja evaporator low stage diukur pada keadaan tanpa beban (temperature ambien), dengan penambahan beban yaitu heater yang dialiri tegangan 0, 120, 180 dan 240 Volt. Hasil yang didapatkan dari pengujian eksperimen ini adalah sistem cascade dengan R407f sebagai refrijeran pengganti dengan Global Warming Potential rendah di low stage tanpa mengganti komponen lainnya beroperasi dengan lebih baik. Dari pengujian didapatkan bahwa sistem memerlukan laju masa R407f yang lebih rendah sehingga lebih hemat pada rata-rata 0.001 kg/s, Temperatur terendah evaporator mencapai -42.5°C dan temperatur kabin -35.15°C, Kompresor membutuhkan daya yang lebih rendah sehingga koefisien prestasi rata-rata yang didapatkan adalah 1.32 sementara rasio pembuangan kalor yang didapat lebih mendekati angka 1 yaitu 1.74. Efektivitas dari evaporator low stage yang didapat secara rata-rata 99.99%, daya keluaran kompresor LS minimum adlaah 75[W] dan maksimum 150[W] sementara efisiensi isentropis kompresor LS maksimum 59.41%. ======================================================================================================= Public awareness for global warming has been increasing in the past few decades. The increasing influence of social media to the society, the increasing global temperature which has become more obvious and the uncertainites in weather and seasons are among some problems which cause this increasing awareness. One of many contributors to the global waming effect is the refrigeration system. Refrigeration system has been used by man mostly to provide temperature comfort and to save goods, Hence; the increasing global temperature tend to stimulate man to install more refrigeration systems which can worsen the threat it may cause. Based on the problems stated above, this experiment is conducted to provide a solution, which is by creating a more eco-friendly refrigeration system. The datas for this researched are obtained from several tests ran in a Cascade refrigeration system, a two-stage refrigeration system which use MC22 (propane) at the high stage while R-407f at the low stage. R-407f is chosen to replace R404a as a more eco-friendly working refrigerant in the Cascade system due to its low pollution level and its thermodynamic and physic properties. Working characteristics at low stage is studied by exposing the system to various cooling loads which are given by installing heaters with 0, 120, 180 and 240 volt; respectively. The results from this research using R-407f as a lower global waming potential substitute at low stage of a Cascade refrigeration system are proven to be better than those with R404a. From the tests, the mass flow rate with R407f is lower at 0.001 kg/s average. The lowest evaporator temperature is -42.5°C while the lowest for refrigerator box temperature is -35.15°C. Compressors at both stages need to produce less power therefore increasing the coefficient of performance to 1.32 average while the heat refejction ratio is 1.74, closer to 1 to that of R404a. The low stage evaporator effectiveness is 99.99% average while the minimum compressor power is 75[W] with maximum 150[W] and the isentropic efficiency of low stage compressor is maximum 59.41%.

Item Type: Thesis (Undergraduate)
Additional Information: RSM 621.56 Pin p
Uncontrolled Keywords: R-407F, Sistem refrijerasi Cascade, Evaporator, Koefisien prestasi, Global Warming Potential
Subjects: T Technology > TP Chemical technology > TP492.3 Refrigeration and refrigerating machinery
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 04 Dec 2019 02:46
Last Modified: 04 Dec 2019 02:46
URI: https://repository.its.ac.id/id/eprint/72183

Actions (login required)

View Item View Item