Instrumentasi Elektrokardiografi Dengan Capacitive Contact Electrode Pada Kursi Untuk Pemantauan Denyut Jantung

Emilia, Monica Regina (2016) Instrumentasi Elektrokardiografi Dengan Capacitive Contact Electrode Pada Kursi Untuk Pemantauan Denyut Jantung. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2212100014-Undergraduate_Thesis.pdf - Accepted Version

Download (2MB) | Preview
[img]
Preview
Text
2212100014-Paperpdf.pdf - Accepted Version

Download (422kB) | Preview
[img]
Preview
Text
2212100014-Presentationpdf.pdf - Presentation

Download (1MB) | Preview

Abstract

Elektrokardiograf merupakan alat yang digunakan untuk merekam sinyal jantung. Elektrokardiograf secara konvensional menggunakan elektroda Ag-AgCl sebagai conductive contact dan kabel sebagai penghubung antara elektroda dengan elektrokardiograf. Walupun sinyal yang dihasilkan memiliki kualitas yang baik, konfigurasi tersebut membatasi ruang gerak pengguna. Oleh karena itu pada tugas akhir ini akan difokuskan pada perancangan Instrumentasi Elektrokardiografi secara indirect menggunakan capacitive electrode. Capacitive electrode di desain menggunakan IC OPA124U yang memiliki input impedansi tinggi. Rangkaian ini dilindungi oleh shield alumunium yang dihubungkan dengan ground untuk mengurangi noise. Respon dari preamp diuji dengan memberikan varian tegangan sebesar 200mV, 500mV, dan 1V baik secara direct maupun indirect dengan penghalang berupa kain. Dari pengujian yang didapatkan terlihat gain dari elektroda terlihat stabil pada angka 3,2 saat frekuensi diatas 10 Hz. Sedangkan saat frekuensi dibawah 10 Hz, gain berbanding lurus dengan besarnya frekuensi. Preamp dibuat sejumlah 2 buah dan sebuah pcb digunakan sebagai grounding. Ketiga sinyal ini kemudian dimasukkan kedalam Penguat Instrumentasi menggunakan IC AD620 dan filter dengan pass band 0,5-60 Hz. Melalui pengujian menggunakan 6 subjek dengan varian pakaian yang berbeda didapatkan bahwa metode pemantauan denyut jantung menggunakan capacitive electrode kualitasnya masih belum sebaik elektroda direct namun elektroda ini mampu mendeteksi kompleks QRS dengan jelas walau tanpa conductive contact. Perhitungan denyut jantung menggunakan mikrokontroler memiliki rata-rata error sebesar 1,79% dibandingkan dengan penghitungan secara manual. ======================================================================================================================== Electrocardiograph is a device used to record a signals from the heart. Conventional electrocardiograph use Ag-AgCl electrode as conductive contact and a cable connecting the electrodes with the electrocardiograph. Even the quality of the signal is good, the configuration of the device limiting user's movement. Therefore, this final project focused on designing an electrocardiography instrumentation using capacitive electrode.Capacitive electrode is designed using OPA124U IC which has a high input impedance. This circuit is shielded with alumunium connected to ground to reduce the noise.The response of the electrode is tested by giving variant voltage of 200mV, 500mV and 1V both direct and indirect with cloth. From the experiment, it can be obtained that gain of the electrode stabilized at 3,2 when the frequency is above 10 Hz. Meanwhile, when the frequency below 10 Hz, the gain is proportional to the magnitude of frequency. 2 of capacitive electrodes placed at the back of the chair and a piece of pcb placed on the cushion as the grounding. All those signals then inserted into the instrumentation amplifier using AD620 and a filter with pass band 0,5 to 60 Hz. From the experiment with 6 different subjects and clothing variation, it can be conclude that the signal quality obtained with capacitive electrode is not as good as conventional electrode but the result shows QRS complexes still can clearly seen without conductive contact. Heart rate measurement using microcontroller had an average error 1,79% compared to manual measurement.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.382 2 Emi i
Uncontrolled Keywords: capacitive electrode, elektrokardiografi, indirect
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK5102.9 Signal processing.
Divisions: Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: ansi aflacha
Date Deposited: 13 Jan 2020 07:55
Last Modified: 13 Jan 2020 07:55
URI: https://repository.its.ac.id/id/eprint/72658