Pengendalian Kebisingan Antar Ruang Berdasarkan Transmission Loss Dan Flanking : Studi Kasus Laboratorium Komputer Dan Ruang Baca

Holis, Akhmad (2014) Pengendalian Kebisingan Antar Ruang Berdasarkan Transmission Loss Dan Flanking : Studi Kasus Laboratorium Komputer Dan Ruang Baca. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2409100018-Undergraduate_Thesis.pdf - Accepted Version

Download (4MB) | Preview
[img]
Preview
Text
2409100018-Presentation.pdf - Presentation

Download (1MB) | Preview
[img]
Preview
Text
2409100018-Paper.pdf - Accepted Version

Download (917kB) | Preview

Abstract

Ruang baca merupakan salah satu tempat yang membutuhkan ketenangan dan kenyamanan supaya para pembaca yang sedang melakukan aktivitasnya tidak merasa terganggu. Salah satu faktor kenyamanan pada ruang baca (studi kasus di Jurusan Teknik Fisika FTI-ITS) adalah dari segi akustik yakni tingkat kebisingan pada ruangan tersebut yang mana sebagian besar bersumber dari laboratorium komputer. Padatnya aktivitas di laboratorium komputer menjadi salah satu sumber bising pada ruang baca yang mana bising tersebut menjalar dari laboratorium komputer ke ruang baca melalui dinding partisi yang menhubungkan kedua ruangan. Penelitian dilakukan dengan cara pengambilan data tingkat tekanan bunyi pada kedua ruangan tersebut. Setiap ruangan memiliki 6 titik pengukuran yang berjarak 1m dari dinding partisi. Pengukuran menggunakan SLM SOLO untuk mendapatkan tingkat tekanan bunyi pada setiap titik pengukuran yang mana setiap titik memiliki jarak 2m antar titik kecuali dua titik yang berdekatan dengan dinding luar bagian selatan dan utara. Dari hasil pengukuran didapatkan bahwa nilai noise reduction dari dinding partisi yang terbuat dari plywood tersebut cukup kecil sehingga sebagian besar bising dari laboratorium komputer tembus ke dalam ruang baca. Untuk mengurangi bising yang terjadi maka dilakukan perancangan dinding partisi double panel homogen menggunakan material fiber cement board dan gypsum board dengan variasi ketebalan dan jarak (cavity) antar panel. Hasil dari perancangan dinding partisi yang paling baik adalah gypsum board 25mm dimana rancangan tersebut memiliki nilai insulasi tunggal (DnTw+Ctr) sebesar 36.2 dB. Sedangkan untuk kontribusi aspek flanking terhadap bising yang terjadi dapat dikatagorikan cukup tinggi yakni maksimal 14.9 dB pada frekuensi 800 Hz dan pada frekuensi 160 Hz. =================================================================================== The reading room is one place that needs and comfort so that readers who are conducting activities not feel disturbed . One of the comfort factor in the reading room ( a case study at the Department of Physics FTI - ITS ) is in terms of the acoustic noise level in the room which is largely sourced from the computer laboratory. Density of activity in the computer laboratory to be one source of noise in the reading room where the noise radiating from the computer laboratory to the reading room through the partition wall that connecting the two rooms . The study was conducted by means of data capture sound pressure level in the second room . Each room has a 6 point measurement within 1m of the partition wall . Measurements using the SLM SOLO to get the sound pressure level at each measurement point where every point has a 2m distance between points except the two points adjacent to the outer wall of the south and the north . From the measurement results showed that the value of noise reduction from partition walls made of plywood is small enough so that most of the noise from penetrating by computer laboratory into the reading room . To reduce the noise that occurs then the design partition wall panel double homogeneous materials using fiber cement board and gypsum board with variations in the thickness and spacing ( cavity ) between panels. The best results of the partition wall design 25mm gypsum board where the design has a single insulation value ( DnTw + Ctr ) of 36.2 dB . As for the contribution of flanking aspect of the noise that occurs can be categorized quite high at 14.9 dB maximum at a frequency of 800 Hz and 160 Hz in frequency.

Item Type: Thesis (Undergraduate)
Additional Information: RSF 620.23 Hol p 3100014054438
Uncontrolled Keywords: Bising, Transmission Loss, Dinding Partisi, Flanking Noise, Noise, Partition Walls.
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD892 Noise control
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis