Reduksi Bising Di Area Turbin Generator Pada Unit Utilitas

Istiningsih, Indhiyar Febryan (2014) Reduksi Bising Di Area Turbin Generator Pada Unit Utilitas. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2410100036-Undergraduate_Thesis.pdf - Accepted Version

Download (1MB) | Preview

Abstract

Tingkat kebisingan yang tinggi pada lingkungan kerja tanpa disadari berdampak buruk terhadap keselamatan dan kesehatan pekerja. Penelitian ini dilakukan untuk melindungi para pekerja di area turbin generator pada unit utilitas dari efek buruk paparan kebisingan yang dapat mengangggu kesehatan. Salah satu upaya yang dilakukan untuk mengatasi permasalahan tersebut adalah dengan memasang enclosure menggunakan pemilihan bahan yang tepat. Dari hasil pengukuran yang telah dilakukan, tingkat kebisingan pada masing-masing lantai di unit ini yaitu pada lantai III dengan nilai TTB sebesar 97,6 dBA, pada lantai II dengan nilai TTB sebesar 91,5 dBA, sedangkan pada lantai I sebesar 91,6 dBA. Dalam pemilihan bahan yang tepat untuk memasang enclosure yaitu didasarkan pada hasil perhitungan nilai transmision loss dari bahan-bahan yang terdapat pada tabel-tabel literatur. Nilai kerapatan massa jenis (W) sangat berperan penting dalam penentuan bahan yang akan digunakan untuk mendesain enclosure. Hasil perhitungan pada masing-masing lantai dapat diketahui bahan yang digunakan yaitu polywood, dalam hal ini hasil perhitungan menunjukkan nilai kerapatan massa jenis yang tertinggi yaitu sebesar 5,05 dan 8,98. Penambahan bahan material dengan bahan polywood setebal 1,26 cm pada lantai I dan II , sedangkan lantai III setebal 2,25 cm, sehingga dapat mereduksi bising dengan tingkat kebisingan sebesar +15 dB. ============================================================================================================ High noise level in the work environment unwittingly adversely affect the safety and health of workers. This study was done to protect the workers in the area at the turbine generator units of utility from the adverse effects of noise exposure that can be harmful to health. One of the efforts made to overcome these problems is to install an enclosure using proper material selection. From the results of measurements that have been carried out, the noise level on each floor in this unit is on the third floor with TTB value of 97.6 dBA, on the second floor with TTB value of 91.5 dBA, while the first floor was 91.6 dBA. In the selection of appropriate materials to install the enclosure is based on the calculation of the transmission loss of the materials contained in the tables literature. Mass density value type (W) are important in determining which materials will be used to design the enclosure. The results of calculations on each floor can be known materials used are polywood, in this case the value of the density calculation results show that the highest density is equal to 5.05 and 8.98. The addition of materials with 1.26 cm thick polywood material on first and second floors, while the third floor of 2.25 cm thick, so it can reduce noise with noise level of +15 dB.

Item Type: Thesis (Undergraduate)
Additional Information: RSF 620.23 Ist r 3100014056780
Uncontrolled Keywords: Tingkat Kebisingan, Enclosure
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD892 Noise control
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Yeni Anita Gonti
Date Deposited: 09 Oct 2020 04:58
Last Modified: 09 Oct 2020 04:58