Sumaryanto, A. (2015) Perencanaan ulang instalasi heater drain pump (HDP) pada PLTU unit 3 PT. PJB UP Gresik. Diploma thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
2112038013-Paper-2112038013-paperpdf.pdf Download (2MB) | Preview |
Preview |
Text
2112038013-NonDegree.pdf Download (7MB) | Preview |
Preview |
Text
2112038013-Presentation-2112038013-presentationpdf.pdf Download (9MB) | Preview |
Abstract
Heater Drain Pump (HDP) adalah pompa yang
digunakan untuk memompa air dari Heater Drain Tank menuju
ke pipa air kondensat. Air heater drain ini memiliki temperatur
yang cukup tinggi sehingga bisa digunakan untuk menambah
suplai air kondensat yang menuju ke Deaerator. Pada PLTU di
PJB UP Gresik terdapat masing – masing 1 pompa pada unit 3
dan 4. Pada tugas akhir ini bertujuan untuk melakukan
perencanaan ulang instalasi dan pemilihan pompa yang sesuai
untuk feed water heater drain system.
Perhitungan dimulai dari kapasitas sehingga kecepatan
setiap section dapat dicari. Kecepatan setiap section ini
digunakan untuk mencari head loss total instalasi. Perhitungan
head, daya dan efisiensi dilakukan secara analitis dan numerik
menggunakan software pipe flow expert.
Pada hasil perhitungan diperoleh kapasitas
,
Head Effektif Instalasi Heff = 171,0353 m dan NPSHA 2,72 m.
Dengan data tersebut maka dipilih pompa dengan kapasitas
, total head 175 m, NPSHR 2,1 m, jumlah stage 7 dan daya
motor . Sehingga dengan kebutuhan tersebut, maka
pemilihan pompa sentrifugal multistage tipe TSM-7
(YOSHIKURA KOGYO) sudah tepat.
==========================================================================================================
Heater Drain Pump (HDP) is a pump that used to
distribute water from Heater Drain Tank to condensate water
pipe. This heater drain water has high temperature so that it can
be used to add condensate water supply that lead to Deaerator.
At PLTU PJB UP Gresik there is one pump on each unit 3 and 4.
This final project is purposed to redesign the installation and
selecting pump that suitable for feed water heater drain system.
The calculation start from capacity so that the speed of
each section can be searched. The speed of each section is used to
find the total head loss installation. The calculation of head,
power and efficiency will be calculated by analytic and numeric
method using pipe flow expert software.
The calculation result acquired capacity is
,
Head Effektif Installation Heff = 171,0353 m and NPSHA 2,72 m.
With such pump data so will be selected pump capacity is
,
total head 175 m, NPSHR 2,1 m, number of stage 7 and motor
power . So with those requitments the selection of
centrifugal multistage pump type TSM-7 (YOSHIKURA KOGYO)
has already correct.
Item Type: | Thesis (Diploma) |
---|---|
Additional Information: | RSM 621.183 Sum p |
Uncontrolled Keywords: | Heater Drain Pump, feed water heater drain system, sentrifugal multistage |
Subjects: | Q Science > QC Physics > QC320 Heat transfer |
Divisions: | Faculty of Industrial Technology > Mechanical Engineering > 21401-(D3) Diploma 3 |
Depositing User: | - Taufiq Rahmanu |
Date Deposited: | 22 Nov 2019 07:00 |
Last Modified: | 22 Nov 2019 07:00 |
URI: | http://repository.its.ac.id/id/eprint/71980 |
Actions (login required)
View Item |