Desain Modifikasi Struktur Gedung Vorza Office Tower Menggunakan Metode Eksternal Prestress

Rifali, Hans Benedict (2019) Desain Modifikasi Struktur Gedung Vorza Office Tower Menggunakan Metode Eksternal Prestress. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111440000096-Undergraduate_Theses.pdf]
Preview
Text
03111440000096-Undergraduate_Theses.pdf

Download (24MB) | Preview

Abstract

Perencanaan Gedung Apartemen Vorza Office Surabaya setinggi 30 lantai ini dirancang menggunakan beton bertulang konvesional pada keseluruhan lantai. Gedung tersebut akan direncanakan ulang menggunakan beton konvensional pada lantai 1 sampai 30 dan menggunakan beton pratekan eksternal pada atap.Pada lantai 30 akan direncanakan sebagai ballromm sebagai penunjang kegiatan yang berada di kawasan Surabaya. Untuk itu, dibutuhkan ruangan yang luas tanpa ada kolom di bagian tengah-tengah ruangan. Gedung ini sebenarnya menggunakan atap rangka baja yang kemudian akan dihitung ulang menggunakanatap pelat beton sehingga diperlukan struktur balok yang dapat menjangkau bentang panjang tersebut dengan dimensi yang relatif kecil namun kuat dan tetap efisien.Salah satu alternatif solusi perancangan lantai 30 tersebut dengan menggunakan struktur beton pratekan eksternal yangmana mengkombinasikan beton berkekuatan tinggi dan baja mutu tinggi dengan cara menarik baja tersebut dan menahannya ke beton sehingga membuat beton dalam keadaan tertekan.Dari perhitungan, hasilnya balok pratekan pada lantai 30 dengan panjang 20 m adalah dimensi 75/125 dengan dua buah tendon VSL 5-19 yang terdiri dari 15 strand.
===============================================================================================================================
Planning 30-storey Vorza Office Surabaya Apartment Building is designed using conventional reinforced concrete on the entire floor. The building will be re-planned using conventional concrete on floors 1 to 30 and using external prestressed concrete on the roof.On the 30th floor, it will be planned as a ballromm to support activities in the Surabaya area. For that, a large room is needed without a column in the middle of the room. This building actually uses the roof of a steel frame which will then be recalculated using a concrete slab roof so that beam structures are needed that can reach these long spans with relatively small but strong dimensions and remain efficient. One alternative design solution for the 30th floor is to use an external prestressed concrete structure which combines high-strength concrete and high-quality steel by pulling the steel and holding it onto the concrete to make the concrete under pressure.From the calculation, the results of prestressed beams on the 30th floor with a length of 20 m are dimensions of 75/125 with two VSL 5-19 tendons consisting of 15 strands.

Item Type: Thesis (Other)
Additional Information: RSS 624.183 4 Rif d-1 2019
Uncontrolled Keywords: Eksternal prestress,conventional concrete,vorza Office Apartment Building,Surabaya
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Hans Benedict Rifali Deno
Date Deposited: 15 Jul 2024 01:20
Last Modified: 15 Jul 2024 01:20
URI: http://repository.its.ac.id/id/eprint/61160