Abstract

Laut memiliki potensial energi yang sangat besar. Energi tersebut dapat dimanfaatkan sebagai power generate dalam menggerakkan turbin untuk menghasilkan listrik. Pemanfaatan energi tersebut tergolong sebagai renewable energi atau energi baru terbarukan. Indonesia memilki potensi energi baru terbarukan sebesar 445 GW yang termasuk didalamnya adalah energi arus laut. Implementasi pembangkit listrik tenaga arus laut masih dalam tahap penelitian dan belum mempunyai implementasi komersial. Sebagai Perusahaan Listrik Negara (PLN), tentunya telah membentangkan jaringannya diseluruh kawasan di Indonesia, oleh karena itu dalam konsep on-grid system, pengoptimalan pemanfaatan energi baru terbarukan ini diharapakan dapat menekan penggunaan energi bahan bakar fosil yang cenderung menghasilkan emisi. Pada tugas akhir ini, akan dilakukan perancangan dan pengujian rangkaian pembangkit listrik energi arus laut pada tahap on-grid system atau terintegrasi dengan jaringan listrik PLN. Penelitian ini akan akan melihat keandalan dari generator yang diputar oleh motor induksi sebagai pengganti turbin. Beberapa peralatan lain yang digunakan yaitu rectifier sebagai penyearah arus gelombang AC ke DC. Kemudian inverter, berguna sebagai perubah sinyal gelombang DC ke AC dan sinchronizing ke grid. Motor induksi yang digunakan pada eksperimen ini dihubungkan menggunakan pulley ke generator sebagai prime mover dan putarannya divariasikan oleh Variable Speed Drive Controller. Sehingga kecepatan generator bisa diatur dengan mengubah frekuensi motor. Pada hasil percobaan menunjukkan, sistem dikatakan sinkron dengan grid ketika frekuensi: 49.5-50.5 Hz; Tegangan: ± 3% (217-226) Vac; serta sudut fasa yang sama atau berhimpit sebesar 120°. Tegangan output generator akan semakin bertambah seiring dengan bertambahnya rpm sesuai dengan persamaan 2.2.1.1. Tegangan terkecil yaitu 18.8 Vac pada rpm 22 dan tegangan terbesar 186.4Vac saat rpm 245 pada sisi V_(L-N). Sedangkan sisi V_(L-L) , tegangan terkecil 32.7Vac dan tegangan terbesar 323 Vac. Besar output tegangan rectifier yang mampu disinkronkan inverter adalah lebih dari 53.5Vdc. Tegangan keluaran rectifier menunjukkan penurunan tegangan ketika dihubungkan dengan grid yang disebabkan oleh pemasangan penampang kabel yang kecil.
==============================================================================================================================
The sea has enormous energy potential. These energies can be used for driving the turbine to produce electricity. Utilization of those energies are included in renewable energy. Indonesia has potential renewable energy of 445GW which one includes ocean current energy. The implementation of a marine power plant is still under research and doesn’t yet have commercial access. As a State Electricity Company (PLN) they have expanded the network throughout the region of Indonesia, therefore in the concept of an on-grid system, optimizing the utilization of renewable energy is expected able to reducing fossil fuel consumption that inclines produce the emissions. In this final project, it will be doing testing and creating the design of the on-grid system which is integrated into the PLN network. This research willing to see the reliability of generator rotated by induction motor as substitutes the turbine. Other types of equipment is rectifier to convert AC to DC current and inverter use to DC-AC converter and grid syncronizing. The induction motor is connected generator by a pulley and its rpm varied by Variable Speed Drive Controller. With the result that generator speed is able to control by changing motor’s frequency. According to the result of the experiment shows when the system called synchronous if they have frequency: 49.5-50.5 Hz; Voltage: ± 3% (217-226) Vac; and similar phase angle, that is 120°. The output voltage of the generator will increase as rising as generator rpm which are appropriate as a formula 2.2.1.1. The smallest voltage is 18.8 Vac in rpm 22 and the greatest one is 186.4Vac in rpm 245 on V_(L-N) side. While on V_(L-L) side, the smallest is 32.7 Vac and the greatest is 323 Vac. The magnitude of rectifier output is able to sync when more than 53.5 Vdc. The output voltage from rectifier shows voltage decrease when it connected to the grid caused by the small cable installation

Item Type: Thesis (Other)
Additional Information: RSSP 621.319 Alw s-1 2019
Uncontrolled Keywords: On-grid, Renewable Energy, Rectifier, Variable Speed Drive Controller
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1519.S68 Hydroelectric power plants
V Naval Science > VM Naval architecture. Shipbuilding. Marine engineering
Divisions: Faculty of Marine Technology (MARTECH) > Marine Engineering > 36202-(S1) Undergraduate Thesis