Perhitungan beban panas pada sistem hidrolik penggerak steam control valve di PT. Petrokimia Gresik unit Pabrik III

Winanda, Juan Andoni (2016) Perhitungan beban panas pada sistem hidrolik penggerak steam control valve di PT. Petrokimia Gresik unit Pabrik III. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2113030017-non degree thesis.pdf]
Preview
Text
2113030017-non degree thesis.pdf

Download (1MB) | Preview
[thumbnail of 2113030017-paperpdf.pdf]
Preview
Text
2113030017-paperpdf.pdf

Download (459kB) | Preview
[thumbnail of 2113030017-presentationpdf.pdf]
Preview
Text
2113030017-presentationpdf.pdf

Download (1MB) | Preview

Abstract

Control valve adalah salah satu katup yang digunakan pada turbin uap untuk mengatur besarnya kapasitas uap yang akan masuk ke rotor turbin. Katup ini digerakan oleh sistem hidrolik yang berjenis electro hidrolik. Sistem hidrolik yang beroperasi pasti akan timbul panas karena fluida yang terkena kerugian mekanis. Sehingga dilakukan penelitian apakah pada sistem hidrolik control valve ini terjadi overheating atau tidak. Penelitian dimulai dengan melakukan pengujian sistem hidrolik dengan simulasi fluidsim, untuk mengetahui cara kerja dari sistem hidrolik control valve. Selanjutnya menghitung heat load dan heat dissipation dari cooler yang kemudian dilakukan pembandingan antara keduanya, sehingga diketahui pada sistem terjadi overheating atau tidak. Dengan dilakukan perhitungan maka didapatkan besarnya gaya pembebanan masing – masing silinder, pada pilot valve sebesar 55019.74 N, pada main cylinder sebesar 172564.21 N. selanjutnya gaya ini dilakukan untuk menghitung heat load dari sistem hidrolik. Maka didapatkan heat load total sebesar 25,238 kW. Berdasarkan data di perusahaan dari cooler hidrolik maka dapat dilakukan perhitungan heat dissipation. Sehingga didapatkan besarnya heat dissipation sebesar . Maka dapat disimpulkan pada sistem tidak terjadi overheating.

=======================================================================================================

Control valve is one kind of valve which is used in a steam turbine to control volume of vapor that will enter the rotor of turbine. This valve operated by electro hidraulic system. In this hidraulic system, heat appeared that comes from mechanic loss of fluids. So that, in this research we will find out is there any overheating appeared. The research began by testing the hydraulic system with simulation fluidsimH, that to know the workings of the hydraulic system control valve. Next calculate the heat load and heat dissipation of the cooler and then do a comparison between the two, so it is known to the system overheating occurs or not . We got the force from the calculation in every cyllinder, in a pilot valve 55019,7 N, in a main cyllinder 1725642,21 N. After that, this forces used to calculate the heat load from the hidraulic system that has a total heat load 25,238 kW. Based on the data that we got from cooler hidraulic, so we can calculate the value of heat dissipation that has value 26,623 kW. Hence, we can conclude overheating did not occur in this hidraulic system.

Item Type: Thesis (Diploma)
Additional Information: RSM 621.84 Win p
Uncontrolled Keywords: Control Valve, Hidrolik, Cooler, Heat Load, Heat Dissipation
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD899.S68 Steam power plants
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21401-(D3) Diploma 3
Depositing User: - Taufiq Rahmanu
Date Deposited: 26 Nov 2019 03:38
Last Modified: 26 Nov 2019 03:38
URI: http://repository.its.ac.id/id/eprint/72031